Checking conditions
- Make
- Volkswagen
- Model
- Gol G3 with Parati and Saveiro, Brazil
- Year
- 1999–2005
- Section
- Component checking › Checking conditions
Checking conditions
Install an injection valve to be tested in a measuring glass of the Flow comparison tester VAG 1602.
Activate the injection valve via Remote control VAG 1348/3A.

The Fuel pump (pre-supply pump) G6 must be activated.
Activate the Remote control VAG 1348/3A during approx. 30 seconds.
Repeat test on the other injection valves. To do this, use new measuring beakers.
After all injection valves have been activated, place the measuring beakers on a horizontal surface and compare the injected quantity. Theoretical value: 85...105 ml per injector.
If the measured values of one or more injection valves are above or below the prescribed specifications:
Renew defective injection valve.
Install in reverse order from the removal. Please note the following:
- Sealing rings in all injector valves must be replaced and slightly lubricated with clean engine oil before installation.
- The injection valves shall be installed vertically on the fuel distributor and fastened with the respective clips.
- Position fuel distributor with locked injection valves in the intake tube pushing evenly.
Parts & tools for this job For 1999 Volkswagen Gol
- PARTEngine gasket setSearch: Volkswagen Gol 1999 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.