Install an injection valve to be tested in a measuring glass of the Injection rate tester VAG 1602.
Activate the injection valve through the Remote control VAG 1348/3A.

The fuel pump should be activated.
Start the Remote control VAG 1348/3A for approx. 30 seconds.
Repeat the test in the other injector valves. For this purpose use measuring glasses.
After activation of all the injection valves, place the measuring glasses on a flat surface and compare the injection volumes. Theoretical value: 85...105 ml per valve.
If the measured values of one or more injection valves are above or below the prescribed specifications:
Renew defective injector valve.
Install in removal reversed order. Pay attention to the following:
- Seal rings in all injector valves must be replaced and must be slightly lubricated with motor clean oil before installation.
- The injection valves should be installed vertically in the fuel distributor and fastened with the respective clamps.
- Position fuel distributor with locked injector valves in the inlet tube and press homogeneously inwards.