Workshop Manuals Factory service & repair Volkswagen
01 4 - Cyl. injection engine (1.0 l)02 4 - Cyl. injection engine03 5 - Speed manual gearbox 013 and 0CA04 Brake systems05 Running gear, axles, steering06 Wheels and Tyres - Specifications07 Heating, air conditioning08 Electrical system09 Electrical: Communication10 General body repairs, interior11 General body repairs, exterior12 4-cyl. injection engine (2-valve)13 4 - Cyl. diesel engine
Volkswagen Gol G4 with Parati and Saveiro, Brazil (2005-2014)04 · Brake systems
04 · Brakes

Leak control

Make
Volkswagen
Model
Gol G4 with Parati and Saveiro, Brazil
Year
2005–2014
Section
Vacuum system - Check › Leak control
Brake systemsLeak control

Leak control

Note

  • Atmospheric air pressure is 1013 mbar at sea level (N.N.)
  • Air pressure lowers as altitude increases (approx. 100 mbar/1000 m of altitude).
  • Local and climate variations also affect vacuum generation.
  • Cold engines, activated air conditioning systems, or simply an idling engine negatively affect vacuum generation.

Previously test all vacuum hoses for damages (e.g. cracks or “ruptures”) as well as proper fitting.

Connect the servo brake vacuum measurement device VAS 6721Chapter

Open closing valve (A) .

Close closing valves (B) and (C).

N47-10210

Operate the engine at service temperature (>60ºC); briefly press the gas pedal once (engine rotation greater than 2,000 rpm).

In normal circumstances (check indications), the generated vacuum must be between 600 and 950 mbar (depending on the engine).

Open closing valve (C) to evacuate the servo brake.

N47-10213

Stop the engine.

Read and register the indicated measurement.

Vacuum must lower by 400 mbar in 12 hours.

In case of greater vacuum drop, you must test the leakage point located in the region of the ...

Brake servoor Retention valve, vacuum hoses with connectors and intake manifold/vacuum pump.

In case of major leaks, vacuum drops abruptly within a few seconds.

Perform vacuum control in the servo brake region:

After generating vacuum, close the closing valve (A) , to test the servo brake vacuum system.

N47-10214

Check the vacuum in the retention valve area, vacuum hose with connectors and suction tube/vacuum pump:

After generating vacuum, close the closing valve (C), to check the vacuum system of the servo brake vacuum measurement device VAS 6721 until the suction tube or vacuum pump.

N47-10210

To facilitate disassembly of adaptor and hose connections, open the closing valve (B) .

Parts & tools for this job For 2005 Volkswagen Gol