Reconnecting battery
- Make
- Volkswagen
- Model
- Golf Mk6 Cabriolet
- Year
- 2011–2016
- Section
- Disconnecting and reconnecting battery › Reconnecting battery
Reconnecting battery
Warning Danger of injury! Comply with the warning notices and safety regulationsChapter!
Comply with the instructions regarding threaded connections of the battery terminals → Chapter.

Note
- After the battery has been reconnected and the ignition is switched on, the ESP and TCS stabilisation programme warning lamp K155 and the warning lamp for electromechanically assisted steering may come on and emit continuous light. The warning lamps will go out automatically when the vehicle is driven at 15 to 20 km/h in a straight line. This has the effect of reactivating the steering angle sender G85.
Push positive cable terminal clamp (2) onto positive battery terminal and tighten securing nut to prescribed torque → Chapter.

Push earth cable terminal clamp (1) onto negative battery terminal and tighten securing nut to prescribed torque → Chapter.
Work through steps listed in table after connecting.
| Procedure | Performed |
|---|---|
| Switch ignition on with ignition key or start button and then switch off again. | |
| Read fault memory: Guided fault finding using vehicle diagnostic tester. | |
| Check time on clock and change as necessary. | |
| Electric window regulators:Completely open then completely close window.Finally, when window is closed, pull the switch until the relay audibly switches.Check convenience mode of the window regulators. The window must close fully in the convenience mode, without holding the switch. | |
| Functional check: check all electrical consumers. |
Table can be printed out if necessary.