01 4-cylinder injection engine (1.4 l direct injection engine, turbocharger)02 4-cyl. direct injection engine (1.8 l and 2.0 l, 4 V, EA 888 gen III, turbocharger, chain drive)03 3-cylinder direct-injection engine (1.0 l engine, 4V, EA 211, turbocharger)04 4-cylinder direct-injection engine (1.2 l engine, 4V, EA 211, turbocharger)05 Engine: 4-Cyl. Common Rail (1.6 l and 2.0 l, 4V, Turbocharger, EA288)06 Fuel supply system - Petrol engines07 Fuel supply system - Diesel engines08 4-cylinder direct-injection engine (1.4 l, natural gas, EA 211, turbocharger)09 Fuel supply system - natural gas engines10 4-cyl. direct injection engine (2.0 l, 4 V, turbocharger, chain drive, generation III) Volkswagen R GmbH11 Fuel supply system – petrol engines, Volkswagen R GmbH12 4-cylinder injection engine (1.6 l engine)13 4-cyl. direct injection engine (1.8 l, 2.0 l, 4 V, turbocharger, chain drive, generation III)14 4-cyl. diesel engine (2.0 l engine, common rail)15 Propshaft and rear final drive16 6-speed manual gearbox 02Q, 0BB and 0FB17 6-speed manual gearbox 02S18 6-speed dual clutch gearbox 0D919 7-speed dual clutch gearbox 0CW20 6-speed manual gearbox 0AJ21 5-speed manual gearbox 0A422 5-speed manual gearbox 0AH23 5-speed manual gearbox 0AF24 6-speed dual clutch gearbox 0D9, Volkswagen R GmbH25 Propshaft and rear final drive Volkswagen R GmbH26 6-speed manual gearbox 0FB Volkswagen R GmbH27 6-speed manual gearbox 02Q28 6-speed automatic gearbox 09G29 Running gear, axles, steering30 Brake system31 Wheels and Tyres Guide32 Heating, air conditioning33 Heating and air conditioning: Auxiliary heater34 Electrical System, General Information35 Electrical system36 Electrical: Communication37 General body repairs, interior38 General body repairs, exterior39 Vehicle-specific paint information
Volkswagen Golf Mk7 Estate (2013-2020)32 · Heating, air conditioning
32 · Heating & A/C

Safety precautions when handling refrigerants

Make
Volkswagen
Model
Golf Mk7 Estate
Year
2013–2020
Section
Safety instructions › Safety precautions when handling refrigerants
Heating, air conditioningSafety precautions when handling refrigerants

Safety precautions when handling refrigerants

Risk of freezing injury caused by refrigerant

When working on the air conditioning system, there is a risk of highly pressurised refrigerant escaping from the system. There is a risk of injury to the skin and parts of the body due to freezing.

Always wear safety gloves.

Always wear safety goggles.

Extract refrigerant, and open the refrigerant circuit immediately afterwards.

If more than 10 minutes passed since the refrigerant has been extracted, do not open the refrigerant circuit prior to extracting refrigerant anew. Due to re-evaporation, pressure will be built up in the refrigerant circuit.

Risk of damage to refrigerant lines

There is a risk of damage to the refrigerant lines due to rupture of the inner foil.

Never bend refrigerant lines to a radius less then 100 mm (r < 100 mm).