If electric drive is renewed, new unit must be installed in zero position (sliding/tilting roof panel closed).
–  Connect electric drive wiring harness connector to sliding/tilting roof wiring harness.
–  Operate switch -1- and count rotations of input pinion -2-: the 0 position of the electric drive is between the end switch-off points -A- and-B-. The end switch-off point -B- is obtained by turning input pinion clockwise, and the end switch-off point-A- by turning anti-clockwise.
-A- end switch-off point, panel tilting function = 2 turns to 0 position
-B- end shutoff point, panel sliding function =∼8.25 turns to zero position

   