Read measured value block > < End output
Fault table
Fault table
  Note
t  The fault table is listed according to the 5 digit fault code on the left.
t  Explanation of the fault types (e.g. “open circuit/short circuit to earth”): → Fault reader operating instructions
t  Before renewing components indicated as being faulty, check the wiring and connectors to these components as well as the earth connections using current flow diagram. This is particularly relevant if faults are output as“occurring sporadically” (SP).
   
-V.A.G 1551- printoutPossible fault causeRectifying fault
00000  
No fault recognizedIf “No fault recognised” appears after carrying out repairs self-diagnosis is ended

   

-V.A.G 1551- printout
Possible fault causeRectifying fault
00955  
Key 1  
 Adaption limit exceeded
t  Key not adapted
t  Key operated more than 200 times beyond range of system
–  Read measured value block; display group number 003 → Chapter, display zone 1...4
00956  
Key 2  
 Adaption limit exceeded  
00957  
Key 3  
 Adaption limit exceeded  
00958  
Key 4  
 Adaption limit exceeded  

   

-V.A.G 1551- printout
Possible fault causeRectifying fault
01038  
Central locking thermo protection  
  
t  Defective wiring or connectors
t  Door lock stiff
–  Read measured value block; Display group number 001 → Chapter, display zone 4
01044  
Control unit incorrectly coded  
  
t  Control unit installed does not correspond to the vehicle equipment
t  Control unit supplied is not programmed or not fully programmed
–  Replace control unit
–  Inform part supplier of the problem

   

-V.A.G 1551- printout
Possible fault causeRectifying fault
01131  
Turn signal activation  
 Undefined switch position
t  Defective wiring or connectors
–  Check wiring and connectors using current flow diagram
–  Perform final control diagnosis → Chapter
01179  
Incorrect key programming  
  
t  Matching of keys (function 10) not performed correctly
–  See description for matching keys with remote control, page → Chapter
–  Read measured value block; display group number 003 → Chapter, display zone 1...4

   

-V.A.G 1551- printout
Possible fault causeRectifying fault
01330  
Central control unit for convenience system -J393-  
 Defective
t  Control unit for central locking remote control -J276- defective
–  Renew control unit for central locking remote control -J276-
 Voltage supply too high
t  Battery A defective or discharged
t  Voltage regulator C1 defective
t  Alternator C defective
–  Check wiring and connectors using current flow diagram
–  Read measured value block; Display group number 001 → Chapter, display zone 1
 Voltage supply too low
t  Battery A defective or discharged
t  Voltage regulator C1 defective
t  Alternator C defective
 

   

Read measured value block > < End output