Test prerequisites
Test prerequisites
l  Radiator and condenser must be clean (clean them if necessary).
l  The V-belt for air conditioner compressor and alternator is correctly tensioned.
l  All air ducts, covers and seals are OK and properly installed.
l  The flaps reach their end positions.
l  The engine is at operating temperature.
l  The evaporator and heating do not draw any uncooled air at highest fresh air blower speed.
With the engine running and the air conditioning system set to full power, check the following points:
l  The fresh air blower is running
l  The radiator fan is running or is switched on.
l  The fresh air and air recirculation flap is set to „recirculate“.
l  The ambient temperature is more than 15o C.
l  The temperature switch for evaporator -E33- is correctly fitted and its switching temperatures are correct.
   