volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Removing and installing compressor bracket - 4 Cyl. petrol engine > < Installing and adjusting cables
Heating, Air conditioning
Refrigerant R134a - Air conditioner with manual controls
Vacuum hose connection diagram
 
N87-0015

Note:

Insertion depth for vacuum hose in vacuum reservoir: 30 mm, push on dimension vacuum hose to plastic pipe (onto stop approx. 15 mm).

  • Hose
    • 3.5 x 2 x 40 mm
  • Plastic pipe
    • 4 x 1 x 540 mm
  • Plastic pipe
    • 4 x 1 x 490 mm
  • Two way valve for fresh/recirculating air flap -N63-
  • Foam pipe
 
N87-0015
  • Non-return valve
    • Direction of suction indicated by arrow
  • Hose
    • 3.5 x 2 x 40 mm
  • T-connection
  • Hose
    • 3.5 x 2 x 40 mm
    • ◆ For Golf syncro vacuum pipe
  • Plastic pipe
    • 4 x 1 x 585 mm
  • Rubber seal
  • Vacuum reservoir
  • Foam pipe
  • Plastic pipe
    • 4 x 1 x 460 mm
 
N87-0015
  • Hose
    • 3.5 x 2 x 130 mm
  • Plastic pipe
    • 4 x 1 x 125 mm
  • Pre-formed hose
  • Reduction hose
    • ◆ Vacuum hose to vacuum unit for fresh/recirculating air flap

Removing and installing compressor bracket - 4 Cyl. petrol engine > < Installing and adjusting cables