Checking intake air temperature sender > < Matching automatic gearbox control unit and throttle valve potentiometer to one another
Digifant Injection and Ignition system (2 valve)
Digifant injection and ignition system
Checking coolant temperature sender

Note:

The work sequence is dependent upon the programme level of the Digifant control unit. Programme level number , connecting fault reader V.A.G 1551 and selecting engine electronics control unit.

  • ● Engine cold
  • ‒ Connect fault reader V.A.G 1551 and select engine electronics control unit (address word 01); selection is carried out with engine idling.
    => Page 01-3
 
→ Indicated on display:
Rapid data transfer     HELP
Select function XX
  • ‒ Input 08 for "Read measured value block" function and confirm with Q.
 
→ Indicated on display:
Read measured value block     HELP
Input display group number XX
  • ‒ Input 01 for display group 01 and confirm with Q.
 
→ Indicated on display:
(1...4 = Display zones)
Read measured value block 1     ⇒
     1     2     3     4

Note:

If something different is indicated on the display:

=> Fault reader operating instructions

 
→ Up to programme level number 1083
037906024D     DIGIFANT     1.7     1083
Coding

(From programme level number 1390 )

  • ‒ Observe coolant temperature figure in display zone 1. The temperature figure must
         Increase uniformly and without interruption.

Notes:

  • ◆ If the display on fault reader jumps by 2...5 °C, it is a control unit fault and not caused by a defective sender.
  • ◆ Open circuit is indicated by - 40 °C.
  • ◆ If irregular engine running occurs in certain temperature ranges and the temperature figure does not increase without interruption, the temperature signal is temporarily interrupted and the sender must be renewed.
  • ‒ Press ⇒ key.
  • ‒ In put 06 for "End output" and confirm with Q.

If the temperature figure does not change:

  • ‒ Carry out electrical check, test step 10
    => Page 01-18 , if necessary renew coolant temperature sender (G62), (first release pressure from cooling system).
 
→ From programme level number 1390
037906024D     DIGIFANT     1.7     1390
Coding
  • ‒ Observe coolant temperature figure in display zone 2. The temperature figure must
         Increase uniformly and without interruption.

Notes:

  • ◆ If the display on fault reader jumps by 2...5 °C, it is a control unit fault and not caused by a defective sender.
  • ◆ Open circuit is indicated by - 40 °C.
  • ◆ If irregular engine running occurs in certain temperature ranges and the temperature figure does not increase without interruption, the temperature signal is temporarily interrupted and the sender must be renewed.
  • ‒ Press ⇒ key.
  • ‒ In put 06 for "End output" and confirm with Q.

If the temperature figure does not change:

  • ‒ Carry out electrical check, test step 10
    => Page 01-18 , if necessary renew coolant temperature sender (G62), (first release pressure from cooling system).

Checking intake air temperature sender > < Matching automatic gearbox control unit and throttle valve potentiometer to one another