volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Test table > < Initiating basic setting
Ecomatic Self-diagnosis
Performing self-diagnosis
Read measured value block
  • ‒ Connect fault reader V.A.G 1551, enter address word "12 Clutch electronics" and advance programme until "Select function XX" is shown on display => from Page 01-33 .
 
→ Indicated on display:
Rapid data transfer      HELP
Select function XX
  • ‒ Press keys 0 and 8. (The function "Read measured value block" is initiated with 08.)
 
→ Indicated on display:
Rapid data transfer      Q
08 - Read measured value block
  • ‒ Confirm entry with key Q.
 
→ Indicated on display:
Read measuring value block
Enter display group number XX

List of selectable display group numbers

Display group No.

Display field

Designation

01

1
2
3
4

Engine speed
Gearbox speed
Accelerator pedal value
Gear information

02

1

2
3
4

Load signal potentiometer -G157-
Clutch movement sender
Battery voltage
Coolant temperature

03

1
2
3
4

Engine speed
Gearbox speed
Clutch actual position
Clutch correct position

04

1
2
3
4

Input information
Input information
Output information
Output information

Display group No.

Display field

Designation

05

1
2
3
4

Engine speed
Battery voltage
Vacant
Vent valve current

06

1
2
3
4

Is not relevant
Is not relevant
Is not relevant
Is not relevant

07

1
2
3
4

Engine speed
Gearbox speed
Vacant
Speed

08

1
2
3
4

Is not relevant
Is not relevant
Is not relevant
Is not relevant

 
→ Indicated on display:
Reading measured value block     1     ⇒
1     2     3     4

(Specification )

  • ‒ There are always 4 display fields in the measured value block (if necessary in physical quantities.)

Notes:

  • ◆ Explanation of values in the individual display fields => Test table, page 01-68 .
  • ◆ If the specifications for the potentiometer -G157- and clutch movement sender -G162- are not attained, carry out the basic setting=> Page 01-61 .
  • ◆ Before replacing individual components check wiring and connectors according to current flow diagram, repair if necessary.

=> "Current flow diagrams, Electrical fault finding and Fitting locations" Binder, Golf 1992 ▸, Vento 1992 ▸

  • ◆ If the printer is switched on, the current display is printed out on the log.
  • ◆ If the specified values are reached in all the display fields:
  • ‒ Press key ⇒.
 
→ Indicated on display:
Rapid data transfer      HELP
Select function XX

Test table > < Initiating basic setting