‒ Note Lambda probe voltage (display zone 3):
|
---|
|
Display zones
|
|
1
|
2
|
3
|
4
|
Display group 116: Lambda probe after catalyst
|
Display
|
xxx ms
|
xxx.x °C
|
x.xxx V
|
xxxxxxxx
|
Indicated
|
Regulating frequency
|
Exhaust gas temperature (calculated)
|
Lambda probe voltage after catalyst
|
Lambda control status after catalyst
|
Working range
|
---
|
0.0...999.9 °C
|
0.000...1.000 V
|
---
|
Specification
|
---
|
min.140.0 °C
|
0.000...1.000 V
(can fluctuate marginally)
|
Relevance
|
|
---
|
---
|
If specification is not attained
, continuation
|
---
|
Continuation
-
‒ Carry out test drive to remove possible residue and repeat the check.
If the specification in display zone 3 is not attained even after a test drive:
-
‒ Check Lambda probe heating
=> Page 24-50
.
-
‒ Rev-up to above 3000 rpm.
If the figure in display zone 3 remains constant => Page 24-46
, evaluating display group 116.
Evaluating display group 116
Display group: 116
|
|
|
Display zone: 3
|
Possible fault cause
|
Fault elimination
|
Approx. 0.435 V
|
Wiring open circuit in wire 4 between Lambda probe and control unit
|
- Check basic voltage=> Page 24-47
|
Approx. 0.440 V
|
Wiring open circuit in wire 3 between Lambda probe and control unit
|
|
Approx. 1.085 V
|
Short to positive in wire 4 between Lambda probe and control unit
|
- Check Lambda probe wiring
=> Page 24-48
|
Approx. 0.000 V
|
Short to earth in wire 4 between Lambda probe and control unit
|
|
Relevance of figures in 8 digit number block
Relevance if display = 1
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Lambda control status (display group 116)
|
|
|
|
|
|
|
|
1
|
Fault in fault memory
|
|
|
|
|
|
|
1
|
|
Fault detected during this diagnosis
|
|
|
|
|
|
1
|
|
|
Diagnosis complete during this drive
|
|
|
|
|
1
|
|
|
|
Diagnosis currently active
|
|
|
|
1
|
|
|
|
|
Lambda control before catalyst active
|
|
|
1
|
|
|
|
|
|
Lambda probe after catalyst ready
|
|
1
|
|
|
|
|
|
|
Both Lambda probes cold
|
1
|
|
|
|
|
|
|
|
Probe heating after catalyst on
|
Checking basic voltage
|