| Close shut-off tap of K-Jetronic pressure tester -V.A.G 1318- (lever at right angles to direction of flow position -B-). |
–
| Operate remote control for V.A.G 1348 -V.A.G 1348/3A- at short intervals, until a pressure of approx. 3 bar has built up. |
WARNING Danger of spray when opening the shut-off tap. Hold container over the free connection of the pressure tester. |
|
–
| If pressure builds up too high, relieve excess pressure by carefully opening shut-off tap. |
–
| Watch pressure drop on pressure gauge. After 10 minutes, pressure must not drop below 2.5 bar. |
If the pressure drops further: |
–
| Check line connections for leaks. |
If no fault in lines/wiring is detected: |
–
| Fuel pump -G23- is defective. Renew fuel delivery unit → Chapter. |
|
|
|