| Bypass contact -1- and contact -2- of plug connector using test cables from auxiliary measuring set -V.A.G 1594C-. Stage 1 of radiator fan -V7- and radiator fan on right of radiator -V35- must start up. |
–
| Bypass contact -2- and contact -3- of plug connector using test cables from auxiliary measuring set -V.A.G 1594C-. Radiator fan -V7- and radiator fan on right of radiator -V35- must start up. |
If fan 1st or 2nd speeds do not run: |
If no wiring fault is detected: |
–
| Renew radiator fan -V7- or right radiator fan -V35-. |
|
|
|