Checking radiator fan > < Removing and installing radiator
Checking continued coolant circulation pump
Checking continued coolant circulation pump
Special tools and workshop equipment required
   
t  Voltage tester -V.A.G 1527B-
  W00-0513
t  Auxiliary measuring set -V.A.G 1594C-
t  Current flow diagram
Test prerequisite
  W00-10008
l  Fuse 16 must be OK.
Test procedure
–  Remove centre, left and right insulation trays: → General body repairs, exterior; Rep. gr.50
  N24-0588
–  Pull 2-pin connector off continued coolant circulation pump -V51--arrow-.
  N19-0278
–  Connect contacts of continued coolant circulation pump -V51- to battery using adapter cables from auxiliary set -V.A.G 1594C-. Continued coolant circulation pump must start up.
If the continued coolant circulation pump -V51- does not run:
–  Renew continued coolant circulation pump -V51-.
If the continued coolant circulation pump -V51- runs:
–  Switch ignition off and on again.
  N19-0175
–  Connect voltage tester -V.A.G 1527B- to connector detached from continued coolant circulation pump -V51- using auxiliary cables from adapter set -V.A.G 1594C-. LED must light up.
  Note
This check must be performed within 10 minutes of switching ignition off.
If LED does not light up:
–  Locate and eliminate open circuit referring to current flow diagram: → Current flow diagrams, Electrical fault finding and Fitting locations.
  N19-0279

Checking radiator fan > < Removing and installing radiator