| After pressure has built up, close cut-off tap -A-. |
–
| Watch pressure drop on pressure gauge. After 10 minutes, pressure must not drop below 3.0 bar. |
–
| Pressure retention valve in fuel pump defective; renew fuel delivery unit → Chapter. |
If the pressure does not drop: |
–
| Pressure retention valve in fuel filter is OK, pressure limiting valve in fuel filter is defective. Renew fuel filter. |
|
|
|