Step 6 (There are no filings in high-pressure pump) |
Caution Ensure that the oil seals of the fuel metering valve -N290- are undamaged. If a seal is damaged, the high-pressure pump must be renewed. |
|
–
| Moisten lower seal of fuel metering valve -N290- with fuel. |
–
| Slide valve into high-pressure pump while turning slightly. |
–
| Screw in both bolts -arrows- finger-tight. |
|
|
|