Removing and installing expansion valve
- Make
- Volkswagen
- Model
- Golf Mk7
- Year
- 2013–2020
- Section
- Refrigerant circuit › Removing and installing expansion valve
Removing and installing expansion valve
Special tools and workshop equipment requiredTorque wrench V.A.G 1331


- The expansion valve atomises incoming refrigerant and regulates the flow so that, depending on the heat transport, the vapour does not become a gas until it reaches the outlet of the evaporator.
Observe instructions when working on refrigerant circuit → Chapter.
Note
- The refrigerant must be extracted beforehand, e.g. with air conditioner service station VAS 6007A.
- The previously used air conditioner service stations can still be used ⇒ Volkswagen Workshop Equipment catalogue.
- To prevent the intrusion of moisture, all components of the refrigerant circuit which have been opened must be sealed with suitable plugs.
- The connecting pipe from charge air cooler must be removed on some vehicles Rep. gr.21Charge air system; Assembly overview - charge air system.

Press release buttons on crankcase breather hose (1) and detach hose from cylinder head cover.
Detach vacuum hoses from air pipe (arrows) to permit access.
Loosen hose clip (3).
Swing air pipe with connecting piece towards rear and pull it off turbocharger.

Unscrew speed nuts (1) and (3).
Fold the heat shield (2) as far forwards as possible (arrow).
Warning Danger from escaping pressurised refrigerant!
Freezing of skin and other body parts.
Extract refrigerant and then immediately open refrigerant circuit.If the refrigerant was extracted more than 10 minutes before the opening of refrigerant circuit, the refrigerant must be extracted again. The pressure in the circuit will increase due to subsequent evaporation.
Extract refrigerant.
Remove bolt (1).

Pull refrigerant line (2) with internal heat exchanger off expansion valve.
Remove bolts (1) and (3).

Carefully pull expansion valve (4) out of heat insulation (2).
Seal off open lines and connections with clean plugs from engine bung set VAS 6122.
Installation is carried out in the reverse order. When installing, note the following:

Renew seals. For versions, refer to Electronic parts catalogue.
Fit seals (1) and (4) on connecting pipes (2) and (3) leading to evaporator.
Press refrigerant pipe (2) by hand into expansion valve.

Start bolt (1) by hand and only then tighten to specified torque.
Note
- There are different versions of the expansion valve (identical housing, but different control characteristic). For correct version refer to Electronic parts catalogue.
- Check refrigerant pipes leading to evaporator for dirt and damage.
- Moisten seals with refrigerant oil before installing.
- Ensure seals are properly seated on connecting pipes of evaporator.
- If heat insulation (2) is missing or improperly installed, it may lead to reduced performance of the air conditioning system (due to changes in the set mapped values through heat radiation).

- Chapter“System overview - refrigerant circuit”
Parts & tools for this job For 2013 Volkswagen Golf
- PARTEngine gasket setSearch: Volkswagen Golf 2013 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.