System overview - refrigerant circuit, Golf GTE
- Make
- Volkswagen
- Model
- Golf Mk7
- Year
- 2013–2020
- Section
- Refrigerant circuit › System overview - refrigerant circuit, Golf GTE
Heating, air conditioningSystem overview - refrigerant circuit, Golf GTE
System overview - refrigerant circuit, Golf GTE
Observe instructions when working on refrigerant circuit → Chapter.

- Electrical air conditioner compressor V470
Assembly overview → Chapter
With control unit for air conditioner compressor J842 and electrical air conditioner compressor V470
Removing and installing → Chapter - Seal
Renewing; for versions, refer to Electronic Parts Catalogue.
Moisten with refrigerant oil before fitting → Chapter - Refrigerant line, low-pressure side
From connection on right longitudinal member to air conditioner compressor
With outlet to heat exchanger for high-voltage battery
Damper weight on refrigerant line ChapterNoteDepending on the version of the refrigerant line and on the production date, this refrigerant line may be fitted with an additional weight (damper weight to reduce noise on refrigerant line). Make sure that this component does not directly rest against any other components or that it cannot contact other components during operation (noise) Electronic Parts Catalogue. - Bolt
22 Nm - Refrigerant line
To condenser.
Different versions (with and without connection for refrigerant pressure and temperature sender G395) Electronic Parts Catalogue - Bolt
22 Nm - Outlet from refrigerant line - high-pressure side
To heat exchanger for high-voltage battery - Seal
Renewing; for versions, refer to Electronic Parts Catalogue.
Moisten with refrigerant oil before fitting → Chapter - Service connection, low-pressure side
Removing and installing → Chapter - Outlet from refrigerant line - low-pressure side
To heat exchanger for high-voltage battery - Connection for pressure sender for refrigerant circuit G805
Only installed for some versions (e.g. not installed in vehicles for North America) Electronic Parts Catalogue - Service connection, high-pressure side
Removing and installing → Chapter - Pressure sender for refrigerant circuit G805
5 Nm
Checking: Use vehicle diagnostic tester in “Guided fault finding” mode and Current flow diagrams, Electrical fault finding and Fitting locations
Removing and installing → Chapter
Only installed for some versions (e.g. not installed in vehicles for North America) Electronic Parts CatalogueNoteIn addition to the differing pressure sender, on vehicles with a G805 or G395 sender, the electrical air conditioner compressor V470 (with control unit for air conditioner compressor J842) and the operating unit for the air conditioning system (the Climatronic control unit J255) are different as well vehicle diagnostic tester in “Guided fault finding” mode and Electronic Parts Catalogue.Depending on the version of the refrigerant line, the G805 may also be installed in vehicles with a refrigerant pressure and temperature sender G395 in order to securely seal the connection fitted with a valve. On these vehicles, the G805 is not connected to the vehicle electrical system. - Outlet from refrigerant line - high-pressure side
To heat exchanger for high-voltage battery - Refrigerant line, high-pressure side
From condenser to connection on right longitudinal member
With outlet to heat exchanger for high-voltage battery
Different versions (with and without connection for pressure sender for refrigerant circuit G805) Electronic Parts Catalogue - Seal
Renewing; for versions, refer to Electronic Parts Catalogue.
Moisten with refrigerant oil before fitting → Chapter - Refrigerant line, low-pressure side
From expansion valve to connection on right longitudinal member
Removing and installing → Chapter - Refrigerant line, high-pressure side
From refrigerant shut-off valve for heater and air conditioner unit N541 to expansion valve
From connection on right longitudinal member to N541
Removing and installing Chapter“Removing and installing expansion valve” and Chapter“Removing and installing refrigerant line with internal heat exchanger” - Seal
Renewing; for versions, refer to Electronic Parts Catalogue.
Moisten with refrigerant oil before fitting → Chapter - Refrigerant shut-off valve for heater and air conditioner unit N541
Checking: Use vehicle diagnostic tester in “Guided fault finding” mode and Current flow diagrams, Electrical fault finding and Fitting locations
Removing and installing → Chapter - Refrigerant line, high-pressure side
From connection on right longitudinal member to refrigerant shut-off valve for heater and air conditioner unit N541
Removing and installing → Chapter - Nut
8 Nm - Seal
Renewing; for versions, refer to Electronic Parts Catalogue.
Moisten with refrigerant oil before fitting → Chapter - Bolt
8 Nm

- Refrigerant line, low-pressure side
From expansion valve to connection on right longitudinal member
Removing and installing → Chapter - Seal
Renewing; for versions, refer to Electronic Parts Catalogue.
Moisten with refrigerant oil before fitting → Chapter - Expansion valve
Different versions. Refer to Electronic Parts Catalogue.
Removing and installing → Chapter - Bolt
Qty. 2.
10 Nm - Seal
Renewing; for versions, refer to Electronic Parts Catalogue.
Moisten with refrigerant oil before fitting → Chapter - Bolt
8 Nm - Refrigerant line, high-pressure side
From refrigerant shut-off valve for heater and air conditioner unit N541 to expansion valve
Refrigerant line from connection on right longitudinal member to N541
Removing and installing Chapter“Removing and installing refrigerant shut-off valve for heater and air conditioner unit N541” and Chapter“Removing and installing refrigerant line with internal heat exchanger” - Heat exchanger for high voltage battery
Checking: Use vehicle diagnostic tester in “Guided fault finding” mode and Current flow diagrams, Electrical fault finding and Fitting locations
Removing and installing → Chapter - Seal
Renewing; for versions, refer to Electronic Parts Catalogue.
Moisten with refrigerant oil before fitting → Chapter - Refrigerant line - high-pressure side (with restrictor)
From N542 to heat exchanger for high-voltage battery
This refrigerant line is fitted with a restrictor → Chapter
To remove, remove refrigerant shut-off valve for high-voltage battery heat exchanger N542Chapter“Removing and installing refrigerant shut-off valve for high-voltage battery heat exchanger N542”, and remove refrigerant line from heat exchanger for high-voltage battery ChapterNoteThe diameter of the restrictor hole is approx. 0.7 mm. Depending on the refrigerant line version, this restrictor is permanently installed or it can be removed. For the removable version a strainer may be fitted to prevent the restrictor hole from being blocked by suspended particles.The restrictor restricts the refrigerant flow to the heat exchanger for high-voltage battery and thus its cooling output when the refrigerant shut-off valve for high-voltage battery heat exchanger N542 is open. - Bolt
8 Nm - Refrigerant shut-off valve for high-voltage battery heat exchanger N542
Checking: Use vehicle diagnostic tester in “Guided fault finding” mode and Current flow diagrams, Electrical fault finding and Fitting locations
Removing and installing → Chapter - Refrigerant line, high-pressure side
Refrigerant line to N542 from outlet in refrigerant line - high-pressure side (from condenser to connection on right longitudinal member) Item - Seal
Renewing; for versions, refer to Electronic Parts Catalogue.
Moisten with refrigerant oil before fitting → Chapter - Refrigerant line, low-pressure side
Refrigerant line from heat exchanger for high-voltage battery to outlet in refrigerant line - low-pressure side (from connection on right longitudinal member to air conditioner compressor) Item - Refrigerant line retainer
Parts & tools for this job For 2013 Volkswagen Golf
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Golf 2013 cabin filter
As an Amazon Associate we earn from qualifying purchases.