Removing
- Make
- Volkswagen
- Model
- Golf Plus
- Year
- 2005–2014
- Section
- Repairing heating system › Removing
‹ Prev Removing and installing fresh air and air recirculation flap control motor V154Next › Installing
Heating, air conditioningRemoving
Removing
Note
- The fresh air and air recirculation flap control motor V154 can be removed and installed without trouble only in the position “fresh air mode stop”. If the control motor should be stopped in a different position and cannot be moved electrically to the position “fresh air mode stop”, it can be pulled off and removed only with difficulty.
- The position of the fresh air and air recirculation flap must not be changed.
Remove glove compartment Rep. gr.68.

Release catches (B) and (C) for retainer (A) on intake duct and remove retainer (A).

Disconnect connector from control motor (B).
Remove fresh air and air recirculation flap control motor V154(B) from intake duct (in direction of arrow).
Note
- The connection between the gears of the control motor and the air flow flap is designed so that the control motor can be removed without trouble only in the position “fresh air operation” (the intake opening for air recirculation above the fresh air and air recirculation flap (A) is closed).
- If the control motor is in a different position and can no longer move, the control motor must not simply be pulled off. First, the control motor must be released from its mounting points (C) with force. During this operation, ensure that gear (D) is not damaged.
‹ Prev Removing and installing fresh air and air recirculation flap control motor V154Next › Installing
Parts & tools for this job For 2005 Volkswagen Golf
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Golf 2005 cabin filter
As an Amazon Associate we earn from qualifying purchases.