Removing
- Make
- Volkswagen
- Model
- Jetta Mk5
- Year
- 2005–2010
- Section
- Air conditioning system with manual controls › Removing
Removing
Remove left footwell vent → Chapter.
Remove left trim panel in footwell Rep. gr.68.
Remove data bus diagnosis interface J533Rep. gr.97.

Remove bolts (3) (9 ± 1.3 Nm).
Do not remove bolts (1).
Do not remove bracket (2).
Press bracket (1) in direction of brake pedal (arrow) and secure it there with a cable tie.

Mark connector (C) to control motor (danger of interchanging with other connectors of same construction).

Disconnect connector (C) on temperature flap control motor V68.
Remove cover (A).
Remove securing bolts (D) (1.4 Nm) and remove temperature flap control motor V68(B).
Release control motor lever (E) from connecting rod (F).