Workshop Manuals Factory service & repair Volkswagen
01 4-cylinder diesel engine (2.0 l engine, common rail, generation II)02 4-cylinder diesel engine (1.6 l engine, common rail)03 5-cylinder injection engine (2.5 l engine, 4-valve)04 4-cylinder diesel engine (2.0 l engine, common rail)05 Fuel supply system - Petrol engines06 4-cylinder injection engine (1.4 l direct injection engine, turbocharger and supercharger)07 4-cylinder injection engine (2.0 l engine)08 4-cylinder injection engine (1.6 l engine, MPI)09 4-cylinder injection engine (hybrid vehicles)10 4-cylinder injection engine (1.8 l, 2 l TFSI engine, generation III)11 4-cylinder injection engine (2.0 l engine, chain drive)12 4-cylinder injection engine (1.2 l direct injection engine, turbocharger)13 4-cylinder injection engine (1.4 l direct injection engine, turbocharger)14 4-cylinder common rail engine (2.0 l, 4V, turbocharger)15 Fuel supply system - Diesel engines16 4-cylinder injection engine (1.2 l engine, 4 V, turbocharger)17 4-cylinder injection engine (1.4 l engine, 4 V, turbocharger)18 5-speed manual gearbox 0AF19 6-speed automatic gearbox 09G20 5-speed manual gearbox 0A421 6-speed dual clutch gearbox 02E22 6-speed manual gearbox 02Q23 6-speed manual gearbox 02S24 7-speed dual clutch gearbox 0AM25 6-speed manual gearbox 0AJ26 Wheels and Tyres Guide27 Running gear, axles, steering28 Brake systems29 Brake system30 Heating, air conditioning31 Electrical System, General Information32 Electrical system33 Hybrid electrical system34 Electrical: Communication35 General body repairs, exterior36 General body repairs, interior37 Vehicle-specific paint information
Volkswagen Jetta Mk6 (2011-2018)32 · Electrical system
32 · Electrical

Preparatory measures for calibration

Make
Volkswagen
Model
Jetta Mk6
Year
2011–2018
Section
Blind spot monitor › Preparatory measures for calibration
Electrical systemPreparatory measures for calibration

Preparatory measures for calibration

Extensive preliminary work is required before actual calibration can be carried out using vehicle diagnosis, testing and information system.

Prerequisites:

Position vehicle on a firm and level surface.Apply parking brake – the vehicle must not be moved while the calibration procedure is being performed.Make sure steering wheel is at centre position with wheels pointing straight ahead.Nobody may be inside vehicle during measurement.Opening and closing the vehicle doors during calibration must be avoided.Special tools and workshop equipment requiredCalibration unit VAS 6350
W00-10488
Vehicle diagnostic tester

Procedure

Connect vehicle diagnostic tester.

Switch on ignition.

Attach 3 wheel bolt adapters (spanner size 17) to each wheel centre mounting VAS 6350/1 for the wheel securing bolts.

N94-10685

Insert measuring paddles in both wheel centre mountings VAS 6350/1, and secure them with clamping nut.

Fit wheel centre mountings VAS 6350/1 onto wheel bolts on both rear wheels.

The turning centre of the wheel centre mounting must be in the turning centre of the wheel.

Note

  • Fit wheel centre mountings VAS 6350/1 onto the wheels so that the “anti-theft wheel bolts” are not connected to the wheel centre mountings.

Adjust measuring paddles with the help of the clamping nuts in such a way that they can move freely just above the floor.

The measuring paddles must not be restricted in movement.The measuring paddles must be vertical.

Position calibration unit VAS 6350 at distance (a) to rear wheels.

A96-10286
Dimension (a ) = 1700 ± 2 mm

Push ON button to switch on spacing laser VAS 6350/2.

N94-10681

Indicated on display of VAS 6350/2:

“- - - m”

Note

  • The laser is switched on at the same time.

VAS 6350/2 Hold spacing laser (2) for distance measurement flush with stop bracket as shown in illustration.

N94-10684
When doing this, make sure that spacing laser VAS 6350/2 is firmly in contact with stop bracket.

Ensure that the “laser beam” for distance measurement is at the bottom enlarged part on the measuring paddle (1).

If this is not the case, adjust height of measuring paddles using lock nuts on wheel centre mountings VAS 6350/1.

Now, briefly press ON button to measure distance.

A96-10289

Indicated on display of VAS 6350/2:

“1.700 m” (specification: 1700 ± 2 mm).

Repeat the measuring process from the left stop bracket to the measuring paddle on the rear left wheel.

Measured distance value must be identical on both sides.

If both measured values are not identical, adjust calibration unit VAS 6350 accordingly.

Attach calibration unit for lane change assist VAS 6350/4 on rear left on mounting of calibration unit VAS 6350.

M94-10210
If assembled correctly, the mains power lead should be fitted to the bottom left of the calibration unit (as seen facing direction of normal travel).Dimension (a) = 656 mm (measured from upper edge of calibration unit to workshop floor).

The dimension is set with the measuring point (arrow) at the base of the calibration unit on the scale of the steel rule (1).

Setting dimension left = 617 mm (read off on measuring scale (1)).

Connect the calibration unit for lane change assist VAS 6350/4 to mains voltage.

Bring the calibration unit VAS 6350 to the horizontal position with the aid of the vial (sight glass) (arrow) by turning the plastic feet.

N94-10686

Put on “laser protection glasses”.

M94-10212

Switch on linear laser VAS 6350/3 on calibration unit VAS 6350.

Align the whole calibration unit VAS 6350 so that the laser beam is focused on the rear of the vehicle in the centre above the VW badge.

Check the spacing on the left and right again between the stop brackets of the calibration unit VAS 6350 and the measuring paddles (1) on the wheel mountings.

N94-10684
Specification: 1700 ± 2 mm

Calibrating lane change assist control unit → Chapter.

Parts & tools for this job For 2011 Volkswagen Jetta