Test procedure
- Make
- Volkswagen
- Model
- LT Mk2
- Year
- 1996–2006
- Section
- Exhaust gas recirculation system › Test procedure
Test procedure
The exhaust gas recirculation function is checked in function 04 (basic setting). Using this method the exhaust gas recirculation valve is pulsed every 10 seconds, so that the extreme values for the exhaust gas recirculation (air mass meter) measured value block 3 can be read in display zone 3.
Connect vehicle diagnosis, testing and information system VAS 5051Chapter. When doing this, the engine must be running at idling speed.
Press key “04 - Basic settings” on display.
Press key 3 for “Display group number 3” and confirm entry with Q key.
| Display group | Display zone | Indicated on display |
|---|---|---|
| 3 | 1 | 900 rpm |
| 2 | EGR n.active | |
| 3 | 500 mg/H | |
| 4 | 0 % |
The display in display zone 2 must fluctuate every 10 seconds between EGR.active and EGRn.active.
The displays in display zones 3 and 4 must fluctuate within following control range:
EGR n.active
Specification display zone 3: 480...520 mg/H (stroke).
Specification display zone 4 0...67 % 5 %
EGR active
Specification display zone 3: 270...400 mg/H (stroke).
Specification display zone 4 95...67 % 100 %
EGR n.active
Specification display zone 3: 290...450 mg/H (stroke).
Specification display zone 4: 0 %
EGR active
Specification display zone 3: 280...350 mg/H (stroke).
Specification display zone 4: 99 %
EGR n.active
Specification display zone 3: 450...470 mg/H (stroke).
Specification display zone 4 0...67 % 5 %
EGR active
Specification display zone 3: 240...280 mg/H (stroke).
Specification display zone 4 95...67 % 100 %
EGR n.active
Specification display zone 3: 430...480 mg/H (stroke).
Specification display zone 4 0...67 % 5 %
EGR active
Specification display zone 3: 190...240 mg/H (stroke).
Specification display zone 4 95...67 % 100 %
EGR n.active
Specification display zone 3: 400...500 mg/H (stroke).
Specification display zone 4: 0 %
EGR active
Specification display zone 3: 100...250 mg/H (stroke).
Specification display zone 4: 99 %
EGR n.active
Specification display zone 3: 420...500 mg/H (stroke).
Specification display zone 4: 0 %
EGR active
Specification display zone 3: 190...260 mg/H (stroke).
Specification display zone 4: 99%
EGR n.active
Specification display zone 3: 400...500 mg/H (stroke).
Specification display zone 4: 0 %
EGR active
Specification display zone 3: 140...260 mg/H (stroke).
Specification display zone 4: 99%
Note
- If a constant 550 mg/H is displayed in display zone 3; Check air mass meter: Chapter.
- Displays in display zone 3 are pressure-dependent and therefore elevation-dependent. The specified values refer to 0 m MSL. If the values displayed deviate greatly due to the geographic elevation, check in display zone 3 if a specified difference of min. 100 mg/h is achieved between displays for EGR.active and EGRn.active.
If the specifications are not obtained:
Checking mechanical exhaust gas recirculation valve → Chapter
Vacuum hose schematic diagram ⇒ Page → Chapter.
Check exhaust gas recirculation valve N18Chapter.
Press key ← twice.
Press function “06-End output”.