Charging totally discharged batteries with battery charger VAS 5900
- Make
- Volkswagen
- Model
- LT Mk2
- Year
- 1996–2006
- Section
- Charging battery › Charging totally discharged batteries with battery charger VAS 5900
Charging totally discharged batteries with battery charger VAS 5900
Warning DANGER!Danger of injury! Observe warning notices and safety regulations Chapter!
Warning
- The terminal polarity protection in operating mode „charging totally discharged batteries/support mode“ is not active. Connect battery charger terminal clamps correctly to battery terminals.
- When charging always set the battery charger to the correct type of battery Operating instructions for battery charger VAS 5900!
- Totally discharged battery is not recognised by battery charger → Chapter.
- Do not press START / STOP button when charger unit cables are connected incorrectly. The charger unit may be damaged.
Batteries with a voltage of less than 2 volts will not be recognised automatically by battery charger VAS 5900.
Special tools and workshop equipment requiredBattery charger VAS 5900
Note
- The battery must have a temperature of at least 10 °C.
- If the battery has cell sealing plugs, do not open them while the battery is being charged.
Switch off ignition and all electrical consumers.
Connect mains plug of battery charger. The last selected operating mode will appear on display → Chapter.
Set battery to respective battery type with INFO.

In the display the symbol (1) for „service charge for wet batteries“ or symbol (2) for „service charge for gel/absorbent glass mat batteries“ will appear.
Set battery capacity (Ah) of battery for charging using respective key „Up“↑ or „Down“↓.
Connect red terminal clamp „+“ to positive terminal on battery.
Connect black terminal clamp „-“ to negative terminal on battery.
Press START / STOP for approx. 5 seconds. The menu „charging totally discharged batteries/support mode“ will be activated.
Press respective button „Up“↑ or „Down“↓ to set respective battery voltage (6 V, 12 V or 24 V).
Note
- If a button is not pressed within 5 seconds the charger will return to the main menu (select operating mode).
Confirm the selected battery voltage with START / STOP.
Then follows the enquiry for "is charger cable terminal polarity correct".
Check polarity of charger unit cables.
Confirm polarity of charger unit cables with START / STOP.
Charger will start charging sequence for totally discharged battery.
Press START / STOP.
Disconnect black terminal clamp „-“ of charger unit from negative terminal on battery.
Disconnect red terminal clamp „+“ of charger unit from positive terminal on battery.
Pull out mains plug of battery charger.