Performing vehicle system test
- Make
- Volkswagen
- Model
- Lupo 6X
- Year
- 1998–2005
- Section
- Repairing brake lines › Performing vehicle system test
Performing vehicle system test
Special tools and workshop equipment requiredVehicle diagnosis, testing and information system VAS 5051



Note
- Ensure that the fault reader is only used with the respective diagnosis cable.
Reading fault memory of all systems using vehicle diagnosis, testing and information system VAS 5051 or vehicle diagnosis and service information system VAS 5052
Switch on ignition.
Indicated on display:

Select operating mode "Guided fault finding" on display (arrow).
Note
- If the display is not as shown in the procedure: Operating instructions for vehicle diagnosis, testing and information system VAS 5051 or Operating instructions for vehicle diagnosis and service information system VAS 5052.
Perform vehicle identification.
The programme now automatically performs a vehicle system test and reads all control units available for this vehicle type.
Press ► Continue button.
Now all faults are listed.
Note
- At this point it is useful to change to operating mode guided functions to carry out further operations with VAS 5051 and to prevent a second vehicle identification on tester.
To do this, press button „operating mode“ and then item „guided functions“.
For further procedure see respective work descriptions e.g. „Resetting service interval display“.
To return to guided fault finding, press button „operating mode“ and then „guided fault finding“.
Warning The vehicle must always be delivered to the customer with fault memory cleared.
If one or more static faults are found in the fault memory, we recommend in agreement with the customer to rectify these faults using guided fault finding.
If only sporadic faults or notes are stored in the fault memory and the customer has no complaints in conjunction with the electronic vehicle system, clear fault memory.
Press ► Continue button again to reach the test plan.
Now complete guided fault finding using „GoTo“ button and then „End“.
All fault memories are read again.
Now it is shown on display that all sporadic faults have been cleared, the diagnosis log is sent "online" automatically.
The vehicle system test is completed.
Parts & tools for this job For 1998 Volkswagen Lupo
- TOOLBrake bleeder kitSearch: one man brake bleeder kit
- FLUIDBrake fluidSearch: brake fluid
- TOOLBrake line flaring toolSearch: brake line flaring tool
As an Amazon Associate we earn from qualifying purchases.