Reconnecting battery
- Make
- Volkswagen
- Model
- Lupo 6X
- Year
- 1998–2005
- Section
- Disconnecting and reconnecting batteries › Reconnecting battery
Reconnecting battery
Warning To increase crash safety, the battery is equipped with a battery isolator. In an accident, the airbag control unit triggers a charge disconnecting the voltage supply cable to the starter. Battery isolation is performed pyrotechnically, with a very small explosive charge. In order to avoid causing the explosion inadvertently when working on the battery or during the battery isolation, you must follow the procedure detailed in the repair manual.
Warning Observe notes for battery pole terminal clamp bolt → Chapter.
First fit positive terminal clamp (2) to battery positive terminal and tighten securing bolt to specified torque Chapter.

Then fit negative terminal clamp (1) to battery negative terminal and tighten securing bolt to specified torque → Chapter.
Carry out work steps as detailed in the following table.
| Procedure | Completed |
|---|---|
| Read fault memory ⇒ Guided fault finding using VAS 5051A. | |
| Electric windows: open all windows completely and close again. | |
| Radio or radio and navigation system: Check function, recode radio if necessary | |
| Check time on clock and reset if necessary. |
If necessary, table can be printed out.