Installing
Place control motor (2) on fresh air and air recirculation flap lever (arrow B).

The fresh air and air recirculation flap lever must be moved by hand depending on the position of the control motor. To do so, remove fresh air blower V2Chapter.
Turn control motor (2) in direction of (arrow D).
Fit securing bolt (3).
Connect voltage supply connector.