Passat (B3)
Fuel pump must be heard to run briefly. If the fuel pump does not run:
Notes:
|
Fuel pumps run:
=> Fault finding with V.A.G 1466 Fuel pump does not run: |
LED does not light up:
LED lights up (voltage supply OK.):
If not open circuit can be found:
Checking delivery rate Test conditions
Test sequence
Warning!
Fuel supply lines are under pressure! Before removing from hose connection wrap a cloth around the connection. Then release pressure by carefully pulling hose off connection.
|
|
*) Minimum delivery cm3/30 seconds **) Voltage at fuel pump with engine stationary and pump running (approx. 2 volts less than battery voltage). Example: During the test a voltage of 12.5 volts is measured at the battery. As the voltage at the pump is approx. 2 volts less than the battery voltage then this will equate to a minimum delivery of 530 cm3/30 s. If the minimum delivery rate is not attained: |
If the minimum delivery rate is now attained:
If the minimum delivery rate is again not attained:
Only when up to now no fault has been detected:
If the delivery rate has been attained but nevertheless you suspect a fuel supply system fault (e.g. intermittent failure of fuel supply system):
|
Note: If the fuel system malfunction is intermittent, you can perform the check during a test drive, to do this a 2nd person is necessary. If the current draw is exceeded:
|