volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Checking knock sensors > < Checking ignition timing control
Digifant injection and ignition system (4-valve)
Digifant injection and ignition system
Checking No. 1 Cyl. recognition sender

Special tools, testers and auxiliary items

  • ◆ Test box V.A.G 1598/18
  • ◆ Hand multimeter V.A.G 1526 or multimeter V.A.G 1715
  • ◆ Adapter set V.A.G 1594
  • ◆ Current flow diagram

Test conditions

  • ● Sender fault is recognised by self diagnosis

Test sequence

 
N28-0007
  • ‒ Pull plug off sender (distributor).
  • ‒ → Connect multimeter to measure voltage with aux. cables from V.A.G 1594 to the outer contacts of the plug.
  • ‒ Switch on ignition.
         Specification: At least 10 V
  • ‒ Switch off ignition
 
N24-0094
  • ‒ → Connect test box V.A.G 1598/18 to control unit wiring loom.
  • ‒ Check wiring between test box and 3 pin connector for open circuit according to current flow diagram.
         Contact 1+socket 33
         Contact 2+socket 44
         Contact 3+socket 45
         Wire resistance: Max. 1.5 ω
  • ‒ Additionally check wires for short to one another.
         Specification: ∞ω

If no wiring fault is detected and voltage was present between contacts 1+3:

  • ‒ Renew sender .

If no wiring fault is detected and no voltage was present between contacts 1+3:

  • ‒ Renew Digifant control unit (J169)
    , item 11 .

Checking knock sensors > < Checking ignition timing control