Digifant injection and ignition system
Renewing rotor arm
Special tools, testers and auxiliary items
-
◆ Locking fluid AMV 185 100 01
The rotor arm is bonded to the shaft. If the rotor arm must be replaced, the old rotor arm must be destroyed. This can be done e.g. by crushing with pliers.
Note:
Do not destroy rotor arm with hammer blows, danger of damaging the distributor shaft or bearings.
-
‒ Carefully remove remains from the shaft and bond on new rotor arm with AMV 185 100 01.
|