Procedure
- Make
- Volkswagen
- Model
- Passat B5
- Year
- 1996–2005
- Section
- Engine control unit › Procedure
Procedure
Connect vehicle diagnosis, testing and information system VAS 5051/ as follows:
Connect connector of the 3 m diagnostic cable with voltage supply VAS 5051/1or 5 m diagnostic cable without voltage supply VAS 5051/3 to diagnostic socket.

Start engine and run at idling speed.
Only if engine does not start:
Switch on ignition.
Press button on display for “Vehicle self-diagnosis”.
Press button “01 - Engine electronics” on display.
The control unit identification and coding are indicated on display.
Press button “02 - Read fault memory” on display.
If no fault is stored in engine control unit “0 fault(s) detected” is displayed.
If faults are stored in the engine control unit, these are shown one below the other on the display.
Press the ← button.
Press button “05 - Clear fault memory” on display.
Press function “06-End output”.