Climatronic - passenger compartment
- Make
- Volkswagen
- Model
- Passat B5
- Year
- 1996–2005
- Section
- Climatronic air conditioning with automatic regulation › Climatronic - passenger compartment
‹ Prev Pin assignment for multi-pin connectors A, B, C and D on back of Climatronic control unitNext › Removing and installing footwell vent temperature sender G192
Heating, air conditioningClimatronic - passenger compartment
Climatronic - passenger compartment
Note
- Parts marked with an “*” can be repaired only in workshops with suitable equipment and specially trained mechanics because the refrigerant must be evacuated beforehand using, for example, the air conditioner service station VAS 6007A or a later model.
- Before removing components marked “**”, disconnect battery Rep. Gr.27.

- Clip
Press up with a screwdriver. - Dust and pollen filter
Removing and installing → Chapter - Intake connecting pipe
- Sunlight penetration photosensor G107
Tasks: controls temperature flap and fresh air blower depending on light intensity
Emergency running in event of failure: Climatronic control unit J255 assumes fixed value
Checking: use vehicle diagnosis, testing and information system VAS 5051A in “guided fault finding” function
Removing and installing → Chapter - Defroster vent
- Side window vent
Removing → Chapter - Dash panel temperature sensor G56 with temperature sensor blower V42
The Climatronic control unit J255, the operating and display unit for Climatronic air conditioning system E87 and the dash panel temperature sensor G56 with temperature sensor blower V42 are combined in one unit which cannot be dismantled.
Checking: use vehicle diagnosis, testing and information system VAS 5051A in “guided fault finding” function
Function: temperature sensor controls temperature flap and fresh air blower, depending on temperature
In event of failure of dash panel temperature sensor G56: continued operation assuming value of +24° C
Renewing and adjusting: “code control unit” and then initiate basic setting using vehicle diagnosis, testing and information system VAS 5051AChapter. - Operating and display unit for Climatronic air conditioning system E87
The Climatronic control unit J255, the operating and display unit for Climatronic air conditioning system E87 and the dash panel temperature sensor G56 with temperature sensor blower V42 are combined in one unit which cannot be dismantled.
Checking: use vehicle diagnosis, testing and information system VAS 5051A in “guided fault finding” function
Operation and function → Chapter.
Removing and installing → Chapter
Renewing and adjusting: “code control unit” and then initiate basic setting using vehicle diagnosis, testing and information system VAS 5051AChapter. - Vent
Removing vents, driver and front passenger sides → Chapter.
Removing centre vents → Chapter. - Dash panel cross member**
Observe installation notes when performing repairs → Chapter - Intermediate defroster piece**
Renewing:
Removing and installing dash panel Rep. Gr.70. - Water drain funnel
Removing → Chapter - Fresh air intake duct temperature sensor G89
Function: temperature sensor controls temperature flap and fresh air blower, depending on temperature
In event of failure: ambient temperature sensor G17 takes over the function.
Checking: use vehicle diagnosis, testing and information system VAS 5051A in “guided fault finding” functionRenewing:Remove compartment on front passenger side Rep. Gr.68.Grasp temperature sensor with hand from below behind the distribution box and evaporator housing.Turn temperature sensor 90 ° and pull out.Moisten rubber seal (15) with oil when installing.For vehicles with a double pedal or reinforced insulation Rep. Gr.70Removing and installing dash panel Rep. Gr.70.Loosen dash panel cross member (4).Observe installation notes when performing repairs → Chapter - Evaporator output temperature sender G263Vehicles 10.00 ▸
Checking: use vehicle diagnosis, testing and information system VAS 5051A in “guided fault finding” functionRenewing:Remove compartment on front passenger side Rep. Gr.68.Grasp sender behind the distribution box with hand from below.Turn sender 90 ° and pull out.Moisten rubber seal (15) with oil when installing. - Seal
Moisten with oil. - Air flow flap control motor V71**
Operates simultaneously fresh air and air recirculation flap
Checking: use vehicle diagnosis, testing and information system VAS 5051A in “guided fault finding” function
Removing → Chapter
Renewing and adjusting: initiate basic setting using vehicle diagnosis, testing and information system VAS 5051AChapter - Fresh air blower V2
Checking: use vehicle diagnosis, testing and information system VAS 5051A in “guided fault finding” function
Removing and installing → Chapter - Fresh air blower control unit J126
Task: continuously variable control of fresh air blower speed depending on voltage
Checking: use vehicle diagnosis, testing and information system VAS 5051A in “guided fault finding” function
Removing and installing → Chapter - Glove box cooling vent
Removing and installing → Chapter - Temperature flap control motor V68
Checking: use vehicle diagnosis, testing and information system VAS 5051A in “guided fault finding” function
Removing → Chapter
Renewing and adjusting: initiate basic setting using vehicle diagnosis, testing and information system VAS 5051AChapter - Central flap control motor V70
Checking: use vehicle diagnosis, testing and information system VAS 5051A in “guided fault finding” function
Removing → Chapter
Renewing and adjusting: initiate basic setting using vehicle diagnosis, testing and information system VAS 5051AChapterNoteVehicles from 11.98 are equipped with a new central flap which differs in having a recess in the upper area. It is thus possible to stop the air supply to the footwell. - Climatronic control unit J255
The Climatronic control unit J255, the operating and display unit for Climatronic air conditioning system E87 and the dash panel temperature sensor G56 with temperature sensor blower V42 are combined in one unit which cannot be dismantled.
Checking: use vehicle diagnosis, testing and information system VAS 5051A in “guided fault finding” function
Removing and installing → Chapter
Renewing and adjusting: “code control unit” and then initiate basic setting using vehicle diagnosis, testing and information system VAS 5051AChapter. - Trim for operating and display unit for Climatronic air conditioning system E87
Unclip using screwdriver. - Centre trim
- Centre vent temperature sender G191
Function: controls centre air distribution and fresh air blower delivery rate dependent upon vent temperature.
Checking: use vehicle diagnosis, testing and information system VAS 5051A in “guided fault finding” function
Removing → Chapter - Intermediate piece**
- Distribution box and housing*, **
With heat exchanger.
With evaporator
Removing and installing → Chapter - Footwell vent temperature sender G192
Function: controls air distribution between defroster and footwell and the fresh air blower speed dependent upon the vent temperature.
Emergency running in event of failure: continued operation assuming temperature of +80° C.
Checking: use vehicle diagnosis, testing and information system VAS 5051A in “guided fault finding” function
Removing and installing → Chapter - Footwell and defroster flap control motor V85
Checking: use vehicle diagnosis, testing and information system VAS 5051A in “guided fault finding” function
Removing → Chapter
Renewing and adjusting: initiate basic setting using vehicle diagnosis, testing and information system VAS 5051AChapter - Heat exchanger*, **
After removal, completely renew coolant Rep. Gr.19.
Refrigerant circuit must be evacuated in order to remove or install heat exchanger.Removing:Remove dash panel Rep. Gr.70Extract refrigerant, e.g. with air conditioner service station VAS 6007A or later model.Remove distribution box and housing → Chapter. - Rear duct, left
Right side is a mirror image - Lower connecting pieces
- Upper connecting pieces
- Footwell vent**Renewing:Removing and installing dash panel Rep. Gr.70.Remove dash panel cross member.Observe installation notes when performing repairs ChapterRemove upper connecting pieces.Carefully raise distribution box and evaporator housing.Pull out footwell vent.
- Securing bolt for dash panel cross member and left side member
Observe installation notes when performing repairs → Chapter - RelayFor radiator fan relay V7 and V35, 1st speed J279
Vehicles ▸ 09. 00: control number 214
Vehicles 10. 00 ▸: control number 373For radiator fan relay V7, 2nd speed J280
Vehicles ▸ 09. 00: control number 213
Vehicles 10. 00 ▸: control number 370For radiator fan run-on relay J397
For vehicles with turbo diesel engine.
Vehicles ▸ 09. 00: control number 214
Vehicles 10. 00 ▸: control number 373
Locations Current flow diagrams, Electrical fault finding and Fitting locations - Magnetic clutch relay J44
Not for engine codes BDN, BDP
Control number 267
Location Current flow diagrams, Electrical fault finding and Fitting locations - Dash panel**
Removing and installing Rep. Gr.70
‹ Prev Pin assignment for multi-pin connectors A, B, C and D on back of Climatronic control unitNext › Removing and installing footwell vent temperature sender G192
Parts & tools for this job For 1996 Volkswagen Passat
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Passat 1996 cabin filter
As an Amazon Associate we earn from qualifying purchases.