Special tools and workshop equipment requiredFault reader V.A.G 1551 (or vehicle system tester V.A.G 1552) with cable V.A.G 1551/3Vehicle stationaryThe battery voltage must be at least 11.5 V.All electrical consumers, e.g. lights and rear window heating, must be switched off.The coolant temperature must be 5 ... 95°C. ⇒ Display group 04, display zone 3Intake air temperature below 60°C ⇒ Display group 04, display zone 4Connect fault reader V.A.G 1551 (V.A.G 1552). Then switch ignition on and select engine control unit with “Address word” 01. (Connect fault reader and select engine control unit → Chapter)
Indicated on display:
Rapid data transfer HELPSelect function XXPress buttons 0 and 2 for function “Read fault memory” and confirm entry with Q button.
The number of faults stored or “No fault recognised!” will be shown on the display.
X Faults recognised!If a fault is stored:
Rectify faults printed out using fault table: SAE P0 or P2 codes → Chapter, SAE P1 or P3 codes → Chapter
If no fault is stored:
Press → button.
Continue with step 3.
Indicated on display:
Rapid data transfer HELPSelect function XXPress keys 0 and 5 for function “Clear fault memory” and confirm entry with Q key.
Note
- The readiness code is reset or deleted whenever the fault memory is cleared.
Indicated on display:
Rapid data transfer ->Fault memory is cleared!Note
- If the ignition is switched off between “Read fault memory” and “Clear fault memory” the fault memory will not be cleared.
Press → button.
Indicated on display:
Rapid data transfer HELPSelect function XXPress keys 0 and 4 for function “Initiate basic settings” and confirm entry with Q key.
Indicated on display:
Basic setting Input display group number XXXPress keys 0, 6 and 0 for “Display group number 60” and confirm entry with Q key.
Indicated on display: (1…4 = display zones)
System in basic setting 60 -> xxx % xxx % x ADP. runningCheck specifications in display zones 3 and 4: Display zone 3: 0...8 Display zone 4: ADP. running, ADP. OK
Indicated on display: (1…4 = display zones)
System in basic setting 60 -> xxx % xxx % 8 ADP. OKEnd adaptation after 30 seconds at the earliest by pressing → button.
Start engine and select engine control unit with “Address word” 01. (Connect fault reader and select engine control unit → Chapter)
Indicated on display:
Rapid data transfer HELPSelect function XXPress keys 0 and 4 for function “Initiate basic settings” and confirm entry with Q key.
Indicated on display:
Basic setting Input display group number XXXNote
- Steps 4 and 5 must be carried out during a road test.
- After the road test, the engine must not be switched off for the further procedures.
- During certain steps, it may occur that a subsequent diagnosis has already been carried out successfully in the background. In this case, continue with the subsequent step.
Observe applicable safety precautions during road test → Chapter.
Observe test conditions → Chapter.
Indicated on display: (1…4 = display zones)
System in basic setting 203 -> 1 2 3 4Accelerate vehicle in first gear until an engine speed of approx. 2500 rpm is reached.
Allow engine to run briefly at approx. 2500 rpm until specification: x x x x x 1 0 0 is displayed in display zone 4.
If the display does not indicate as described:
Press → button.
Read fault memory → Chapter.
If the display indicates as described:
Press button 3 (V.A.G 1551) or button ↑ (V.A.G 1552).
Indicated on display: (1…4 = display zones)
System in basic setting 204 -> 1 2 3 4Accelerate vehicle until an engine speed of over 3000 rpm is reached.
Then close throttle abruptly. Specification following overrun in display zone 4: x x x x x 1 0 0
Note
- “Overrun” display must be achieved once for approx. three seconds. Drive in 1st gear to do this.
If the display does not indicate as described:
Press → button.
Read fault memory → Chapter.
If the display indicates as described:
Press button 3 (V.A.G 1551) or button ↑ (V.A.G 1552).
Note
- The following steps can be carried out with the accelerator and brake pedals depressed constantly.
Allow engine to idle.
Indicated on display: (1…4 = display zones)
System in basic setting 205 -> 1 2 3 4Depress brake pedal and hold.
Depress accelerator to full throttle position.
Engine revolutions are raised by engine control unit to approx. 1800 rpm.
Allow engine to run at increased speed until specification: x x x x x 1 0 0 is displayed in display zone 4.
If the display does not indicate as described:
Press → button.
Read fault memory → Chapter.
If the display indicates as described:
Press the C button.
Indicated on display:
Basic setting Input display group number XXXPress keys 2, 0 and 8 for “Display group number 208” and confirm entry with Q key.
Indicated on display: (1…4 = display zones)
System in basic setting 208 -> 1 2 3 4Depress brake pedal and hold.
Depress accelerator to full throttle position.
Engine revolutions are raised by engine control unit to approx. 1800 rpm.
Allow engine to run at increased speed until specification: x x x x x 1 0 0 is displayed in display zone 4.
If the display does not indicate as described:
Press → button.
Read fault memory → Chapter.
If the display indicates as described:
Press button 3 (V.A.G 1551) or button ↑ (V.A.G 1552).
Indicated on display: (1…4 = display zones)
System in basic setting 209 -> 1 2 3 4Depress brake pedal and hold.
Depress accelerator to full throttle position.
Engine revolutions are raised by engine control unit to approx. 1800 rpm.
Allow engine to run at increased speed until specification: x x x x x 1 0 0 is displayed in display zone 4.
If the display does not indicate as described:
Press → button.
Read fault memory → Chapter.
If the display indicates as described:
Press button 3 (V.A.G 1551) or button ↑ (V.A.G 1552).
Indicated on display: (1…4 = display zones)
System in basic setting 210 -> 1 2 3 4Depress brake pedal and hold.
Depress accelerator to full throttle position.
Engine revolutions are raised by engine control unit to approx. 1800 rpm.
Allow engine to run at increased speed until specification: x x x x x 1 0 0 is displayed in display zone 4 after approx. 40 seconds.
If the display does not indicate as described:
Press → button.
Read fault memory → Chapter.
If the display indicates as described:
Press button 3 (V.A.G 1551) or button ↑ (V.A.G 1552).
Indicated on display: (1…4 = display zones)
System in basic setting 211 -> 1 2 3 4Depress brake pedal and hold.
Depress accelerator to full throttle position.
Engine revolutions are raised by engine control unit to approx. 1800 rpm.
Allow engine to run at increased speed until specification: x x x x x 1 0 0 is displayed in display zone 4 after approx. 40 seconds.
If the display does not indicate as described:
Press → button.
Read fault memory → Chapter.
If the display indicates as described:
Press button 3 (V.A.G 1551) or button ↑ (V.A.G 1552).
Indicated on display: (1…4 = display zones)
System in basic setting 212 -> 1 2 3 4Depress brake pedal and hold.
Depress accelerator to full throttle position.
Engine revolutions are raised by engine control unit to approx. 1800 rpm.
Allow engine to run at increased speed until specification: x x x x x 1 0 0 is displayed in display zone 4 after approx. 80 seconds.
If the display does not indicate as described:
Press → button.
Note
- During this step, it may occur that the catalytic converter is no longer at the required temperature. Therefore, switch to “Reading measured value block” mode and then to display group 046. Run the engine at approx. 3500 rpm to bring the catalytic converter temperature to at least 350°C and repeat this step Anchor.
Read fault memory → Chapter.
If the display indicates as described:
Press the C button.
Indicated on display:
Basic setting Input display group number XXXPress keys 2, 1 and 6 for “Display group number 216” and confirm entry with Q key.
Indicated on display: (1…4 = display zones)
System in basic setting 216 -> 1 2 3 4Depress brake pedal and hold.
Depress accelerator to full throttle position.
Engine revolutions are raised by engine control unit to approx. 1800 rpm.
Allow engine to run at increased speed until specification: x x x x x 1 0 0 is displayed in display zone 4 after approx. 75 seconds.
If the display does not indicate as described:
Press → button.
Read fault memory → Chapter.
If the display indicates as described:
Press the C button.
Indicated on display:
Basic setting Input display group number XXXPress keys 2, 1 and 8 for “Display group number 218” and confirm entry with Q key.
Indicated on display: (1…4 = display zones)
System in basic setting 218 -> 1 2 3 4Depress brake pedal and hold.
Depress accelerator to full throttle position.
Engine revolutions are raised by engine control unit to approx. 1800 rpm.
Allow engine to run at increased speed until specification: x x x x x 1 0 0 is displayed in display zone 4.
Note
- This procedure may take approx. 4 minutes.
If the display does not indicate as described:
Press → button.
Read fault memory → Chapter.
If the display indicates as described:
Press the C button.
Indicated on display:
Basic setting Input display group number XXXPress keys 2, 2 and 0 for “Display group number 220” and confirm entry with Q key.
Indicated on display: (1…4 = display zones)
System in basic setting 220 -> 1 2 3 4Depress brake pedal and hold.
Depress accelerator to full throttle position.
Engine revolutions are raised by engine control unit to approx. 1800 rpm.
Allow engine to run at increased speed until specification: x x x x x 1 0 0 is displayed in display zone 4.
If the display does not indicate as described:
Press → button.
Read fault memory → Chapter.
If the display indicates as described:
Press the C button.
Indicated on display:
Basic setting Input display group number XXXPress keys 2, 2 and 2 for “Display group number 222” and confirm entry with Q key.
Indicated on display: (1…4 = display zones)
System in basic setting 222 -> 1 2 3 4Depress brake pedal and hold.
Depress accelerator to full throttle position.
Engine revolutions are raised by engine control unit to approx. 1800 rpm.
Allow engine to run at increased speed until specification: x x x x x 1 0 0 is displayed in display zone 4 after approx. 30 seconds.
If the display does not indicate as described:
Press → button.
Read fault memory → Chapter.
If the display indicates as described:
Press the C button.
Indicated on display:
Basic setting Input display group number XXXPress keys 2, 2 and 5 for “Display group number 225” and confirm entry with Q key.
Indicated on display: (1…4 = display zones)
System in basic setting 225 -> 1 2 3 4Depress brake pedal and hold.
Depress accelerator to full throttle position.
Engine revolutions are raised by engine control unit to approx. 1800 rpm.
Allow engine to run at increased speed until specification: x x x x x 1 0 0 is displayed in display zone 4 after approx. 15 seconds.
If the display does not indicate as described:
Press → button.
Read fault memory → Chapter.
If the display indicates as described:
Press the C button.
Indicated on display:
Basic setting Input display group number XXXPress keys 2, 2 and 7 for “Display group number 227” and confirm entry with Q key.
Indicated on display: (1…4 = display zones)
System in basic setting 227 -> 1 2 3 4Depress brake pedal and hold.
Depress accelerator to full throttle position.
Engine revolutions are raised by engine control unit to approx. 1800 rpm.
Allow engine to run at increased speed until specification: x x x x x 1 0 0 is displayed in display zone 4 after approx. 60 seconds.
If the display does not indicate as described:
Press → button.
Read fault memory → Chapter.
If the display indicates as described:
Press the C button.
Note
- After this step, the engine control unit restores idling speed status.
Release accelerator and brake pedals.
Allow engine to idle.
Indicated on display:
Basic setting Input display group number XXXPress keys 2, 1 and 6 for “Display group number 216” and confirm entry with Q key.
Indicated on display: (1…4 = display zones)
System in basic setting 216 -> 1 2 3 4Allow engine to run at idling speed until specification: x x x x x 1 0 0 is displayed in display zone 4 after approx. 30 seconds.
If the display does not indicate as described:
Press → button.
Read fault memory → Chapter.
If the display indicates as described:
Press the C button.
Indicated on display:
Basic setting Input display group number XXXPress keys 2, 2 and 9 for “Display group number 229” and confirm entry with Q key.
Indicated on display: (1…4 = display zones)
System in basic setting 229 -> 1 2 3 4Allow engine to run at idling speed until specification: x x x x x 1 0 0 is displayed in display zone 4 after approx. 30 seconds.
If the display does not indicate as described:
Press → button.
Read fault memory → Chapter.
If the display indicates as described:
Press the C button.
Indicated on display:
Basic setting Input display group number XXXPress keys 2, 3 and 1 for “Display group number 231” and confirm entry with Q key.
Indicated on display: (1…4 = display zones)
System in basic setting 231 -> 1 2 3 4Allow engine to run at idling speed until specification: x x x x x 1 0 0 is displayed in display zone 4 after approx. 40 seconds.
If the display does not indicate as described:
Press → button.
Read fault memory → Chapter.
If the display indicates as described:
Press → button.
Read readiness code out → Chapter.
Switch off ignition.
Parts & tools for this job For 1996 Volkswagen Passat
- PARTSpark plugsSearch: Volkswagen Passat 1996 spark plugs
- TOOLSpark plug socketSearch: spark plug socket
- TOOLSpark plug gap toolSearch: spark plug gap tool