Workshop Manuals Factory service & repair Volkswagen
01 4-cylinder injection engine (1.8 and 2.0 l engine, chain drive)02 4-cylinder common rail engine (2.0 l, EA189)03 4-cylinder injection engine (2.0 l engine, turbocharger)04 4-cylinder injection engine (1.4 and 1.6 l direct injection)05 4-cylinder injection engine (2.0 l direct injection)06 4-cylinder injection engine (1.4 l direct injection engine, turbocharger)07 4-cylinder common rail engine (1.6 l, EA189)08 4-cylinder diesel engine (1.9 l engine)09 4-cylinder diesel engine (2.0 l engine, 4 valve)10 Fuel supply system - Diesel engines11 Fuel supply system - natural gas engines12 4-cylinder diesel engine (2.0 l engine, 2 valve)13 4-cylinder injection engine (1.6 l roller rocker finger)14 6-cylinder injection engine (direct injection)15 6-cylinder injection engine Volkswagen R GmbH16 4-cylinder direct-injection engine (1.4 l, natural gas, EA 111, turbocharger, supercharger)17 7-speed dual clutch gearbox 0AM18 Propshaft and rear final drive19 6-speed automatic gearbox 09M20 6-speed automatic gearbox 09G21 6-speed manual gearbox 02Q22 6-speed manual gearbox 02S23 6-speed dual clutch gearbox 02E24 6-speed manual gearbox 0AJ25 6-speed dual clutch gearbox 02E Volkswagen R GmbH26 5-speed manual gearbox 0A427 6-speed manual gearbox 02S, four-wheel drive28 6-speed manual gearbox 02Q four-wheel drive29 Propshaft and rear final drive Volkswagen R GmbH30 5-speed manual gearbox 0AH31 Wheels and Tyres Guide - Standard32 Brake systems33 Running gear, axles, steering34 Heating, air conditioning35 Heating and air conditioning: Supplementary heater36 Electrical: Communication37 Electrical system38 General body repairs, interior39 General body repairs, exterior
Volkswagen Passat B6 (2005-2010)34 · Heating, air conditioning
34 · Heating & A/C

Heating, air conditioning (General notes): Repair instructions

Make
Volkswagen
Model
Passat B6
Year
2005–2010
Section
Repair instructions › General notes
Heating, air conditioningGeneral notes

General notes

Only work on the refrigerant circuit in well ventilated rooms. Note that within a radius of 5 m there must be no assembly pits, manholes or cellar access stairs. Switch on the available exhaust gas extraction systems.

Reason:

Escaping refrigerant is not only transparent and odourless, but also heavier than air, i.e. oxygen is being displaced. If, despite observing all safety precautions, refrigerant gas still escapes, there is a danger of suffocation in badly ventilated rooms or assembly pits which cannot be perceived in advance.

Note

  • The mixture of refrigerant gas and air which forms due to escaping refrigerant must not be inhaled. Extract the gas/air mixture using appropriate exhaust gas extraction systems (workshop fume extraction system).

Do not weld, braze or soft-solder any parts of the charged air conditioning system. This also applies to welding and soldering work on the vehicle when the danger exists that parts of the air conditioning system may heat up.

Reason:

Heat leads to high pressure in the system which may cause the system to burst.

Precautions:

Drain refrigerant circuit → Chapter.

Note

  • Damaged or leaking components of the air conditioning system must not be repaired by welding or soldering. They must always be renewed.

When performing repair work on the air conditioning system, all opened components and line connections of the air conditioning systems must be closed immediately.

Reason:

If components of the air conditioning system remain open for a longer period of time, humidity will enter the system. If an air conditioning system was kept open for a longer period of time, parts of the system must be renewed before refilling the system.

Parts & tools for this job For 2005 Volkswagen Passat

As an Amazon Associate we earn from qualifying purchases.