Functional description
The auxiliary heater can be started by means of the remote control, the instant heating button E537 or appropriate programming in the dash panel insert. The booster heater is started automatically by the vehicle electronics system once all the necessary preconditions have been met → Chapter.
Initially, the fresh air blower V2 and the combined glow plug with flame monitoring Q8 are subjected to a functional test and then the glow plug with flame monitoring Q8 goes through a preheating phase.
The subsequent starting process depends on the coolant temperature, among other things, and can therefore vary in the amount of time it takes. The fuel is supplied, the glow plug with flame monitoring Q8 is switched off in stages and the flame monitor is activated.
After completion of the starting phase, the unit operates under full load and further load control (sparking mode, full load, partial load and controlled waiting period) takes place on the basis of the following coolant temperature thresholds.
Change from full load to partial load: approx. 82 °C
Change from partial load to controlled waiting period: approx. 88 °C
Change from full load to partial load: approx. 84 ℃
Change from partial load to controlled waiting period: approx. 88 °C
The reference resistance of the glow plug with flame monitoring Q8 is automatically re-determined during the starting or run-on phase, depending on the unit. This is done to compensate for ageing-related changes.
As a consequence of this calibrating procedure, processes that are affected can also require more time.
After the maximum run time of 60 min expires or after manual shutdown by means of the remote control or the instant heating button E537, the auxiliary heater is switched off.
The booster heater is switched off if at least one of the defined switch-on criteria is no longer met → Chapter.
After switch-off, operation of the metering pump V54 is stopped immediately.
The combustion air blower V6 and the glow plug with flame monitoring Q8 continue to operate for a limited time in order to burn the remaining fuel still in the system and to cool the burner components.
The run-on period of the heater can vary depending on the software version and load level at the time of switch-off.