Workshop Manuals Factory service & repair Volkswagen
01 4-cylinder injection engine (1.4 l direct injection engine, turbocharger)02 4-cyl. direct injection engine (1.8 l and 2.0 l, 4 V, EA 888 gen III, turbocharger, chain drive)03 Fuel supply system - Petrol engines04 Fuel supply system - Diesel engines05 4-cylinder common rail engine (1.6 l and 2.0 l, 4V, turbocharger, EA288)06 4-cylinder common rail engine (2.0 l, 4V, bi-turbo, EA288)07 Fuel supply system - petrol engines, hybrid vehicles08 4-cylinder injection engine (hybrid)09 Propshaft and rear final drive10 6-speed dual clutch gearbox 0D911 7-speed dual clutch gearbox 0CW12 6-speed dual clutch gearbox 0DD, hybrid vehicles13 6-speed manual gearbox 0AJ14 6-speed manual gearbox 02S15 6-speed manual gearbox 02Q, 0BB and 0FB16 7-speed dual clutch gearbox 0DL17 Brake system18 Running gear, axles, steering19 Wheels and Tyres Guide20 Brake system (hybrid)21 Heating, air conditioning22 Heating and air conditioning: Auxiliary heater23 Electrical: Communication24 Electrical system25 Vehicle-specific paint information26 General body repairs, interior27 General body repairs, exterior
Volkswagen Passat B8 (2014-2023)23 · Electrical: Communication
23 · Electrical

Calibrating reversing camera R189

Make
Volkswagen
Model
Passat B8
Year
2014–2023
Section
Reversing camera system › Calibrating reversing camera R189
Electrical: CommunicationCalibrating reversing camera R189

Calibrating reversing camera R189

Make sure all necessary prerequisites are fulfilled Anchor.

Connect vehicle diagnostic tester.

Fitting the wheel centre mounting VAS 6350/1:

Check the bolt hole circle pattern on the wheels.

Prepare wheel centre mountings VAS 6350/1 as required.

To do so, secure three wheel bolt adapters to each wheel centre mounting VAS 6350/1 to match the hole circle.

Position paddles on both wheel centre mountings VAS 6350/1 and secure each paddle with clamping bolt.

Fit wheel centre mountings VAS 6350/1 onto wheel securing bolts on rear axle.

N94-10685

Wheel centre mountings VAS 6350/1 are positioned and secured in the adapters by the “O-rings”.

Note

  • When fitting the wheel centre mountings VAS 6350/1 onto the wheels, make sure that the wheel centre mountings VAS 6350/1 are not mounted on any “anti-theft” wheel bolts that might be installed.

Adjust paddles using clamping bolts so that they can move freely just above the floor. Make sure the paddles can move freely.

Assemble and set up calibration unit VAS 6350Chapter.

Determining the distance:

Switch on spacing laser VAS 6350/2.

The following display appears:
A91-12101

The display shows how the spacing laser VAS 6350/2 must be fitted. Press the respective button.

A91-12100
Fit with front edge.Fit with rear edge.

Hold spacing laser VAS 6350/2(2) flush with bracket on one side of the calibration unit as shown in illustration. Spacing laser VAS 6350/2(2) must make firm contact with bracket.

N94-10684

Briefly press the measurement button.

The laser is switched on.

Laser beam from spacing laser VAS 6350/2(2) must hit lower, larger part of paddle (1).

If this is not the case, position of paddles must be corrected accordingly using clamping bolts on wheel centre mounting VAS 6350/1.

Hold spacing laser VAS 6350/2 in locating bracket on calibration unit VAS 6350 with one hand while laser beam is visible on paddle.

Press measuring button briefly to measure distance.

Make a note of the distance.

Perform same measuring procedure for front wheel on other side of calibration unit VAS 6350.

Measured distance value must be identical on both sides.

If the value is not identical:

Adjust calibration unit VAS 6350 until values on both sides are identical.

When adjusting, make sure that linear laser VAS 6350/3 hits centre of Volkswagen emblem and spirit level display also remains centred. If necessary, readjust accordingly.

Determining dimension (H):

Measure height of calibration unit VAS 6350: dimension (H) (top edge of platform - floor).

A91-11140

Make sure that spacing laser VAS 6350/2 is set correctly (fitted with front edge).

The display shows how the spacing laser VAS 6350/2 must be fitted. Press the respective button.

A91-12100
Fit with front edge.Fit with rear edge.

Note the reading for the height of the calibration unit VAS 6350.

Note

  • The vehicle shown in the illustration may differ from the actual vehicle.
N91-12211

Measure (dimension B) between the centre of the reversing camera lens and the wheel support surface using a commercially available folding ruler.

Note the reading for dimension (B).

The measured distance as well as the height of the calibration unit and the centre height of the reversing camera lens must now be entered in “millimetres” into the vehicle diagnostic tester.

Performing the calibration

Connect vehicle diagnostic tester.

Select Diagnosis mode, and start diagnosis.

Select Test plan tab.

Push Select own test button, and select the following menu items one after the other:

  • Body
  • Electrical system
  • 01 - On Board Diagnostic capable systems
  • 6C - Reversing camera system
  • 6C - Reversing camera, functions
  • 6C - Calibration

From this point on, guidance during the calibration process will be provided by the vehicle diagnostic tester.

Warning Make sure there is no light reflection on the calibration board.
Light reflections will impair the image recognition of the reversing camera R189 and might make calibration impossible.

Parts & tools for this job For 2014 Volkswagen Passat

As an Amazon Associate we earn from qualifying purchases.