01 4-cylinder injection engine (1.4 l direct injection engine, turbocharger)02 4-cyl. direct injection engine (1.8 l and 2.0 l, 4 V, EA 888 gen III, turbocharger, chain drive)03 Fuel supply system - Petrol engines04 Fuel supply system - Diesel engines05 4-cylinder common rail engine (1.6 l and 2.0 l, 4V, turbocharger, EA288)06 4-cylinder common rail engine (2.0 l, 4V, bi-turbo, EA288)07 Fuel supply system - petrol engines, hybrid vehicles08 4-cylinder injection engine (hybrid)09 Propshaft and rear final drive10 6-speed dual clutch gearbox 0D911 7-speed dual clutch gearbox 0CW12 6-speed dual clutch gearbox 0DD, hybrid vehicles13 6-speed manual gearbox 0AJ14 6-speed manual gearbox 02S15 6-speed manual gearbox 02Q, 0BB and 0FB16 7-speed dual clutch gearbox 0DL17 Brake system18 Running gear, axles, steering19 Wheels and Tyres Guide20 Brake system (hybrid)21 Heating, air conditioning22 Heating and air conditioning: Auxiliary heater23 Electrical: Communication24 Electrical system25 Vehicle-specific paint information26 General body repairs, interior27 General body repairs, exterior
Volkswagen Passat B8 (2014-2023)21 · Heating, air conditioning
21 · Heating & A/C

Checking condensation drainage

Make
Volkswagen
Model
Passat B8
Year
2014–2023
Section
Front heater and air conditioning unit › Checking condensation drainage
Heating, air conditioningChecking condensation drainage

Checking condensation drainage

General body repairs, interior

Checking

Remove right centre console trim in footwell General body repairs, interiorRep. gr.68Centre console; Assembly overview - centre console.

Carefully fold back floor covering in area of condensation drain hose so that condensation drain hose is visible.

Lug (arrow) on connecting piece must engage in guide (2).

A87-11363

Insert the condensation drain hose (6) in the body opening until it is heard to engage.

A87-11426

Note

  • It must be possible to push condensation drain hose (1) onto the heater and air conditioning unit connection without tension.
  • The condensation drain hose must be fitted securely to the condensation drain connection on the tunnel.
  • The sealing lip (2) must not be seated loosely on body aperture.
  • The retainer tabs (arrows) must be fully engaged.

Specified torques

  • Centre console; Assembly overview - centre console General body repairs, interiorRep. gr.68Centre console; Assembly overview - centre console