Safety precautions when handling refrigerants
- Make
- Volkswagen
- Model
- Passat NMS, US and China
- Year
- 2011–2019
- Section
- Notes on safety › Safety precautions when handling refrigerants
Safety precautions when handling refrigerants
When working on the air conditioning system, refrigerant may escape under high pressure. Skin and other parts of the body may be frozen.
Always wear safety gloves.
Always wear safety goggles.
Extract refrigerant, and open the refrigerant circuit immediately afterwards.
If more than 10 minutes have passed since the refrigerant was extracted, repeat the extraction process before opening the refrigerant circuit. Continued evaporation will cause pressure to develop again in the refrigerant circuit.
Refrigerant lines may be destroyed through tears in the inner foil.
Never bend refrigerant lines to a radius less than 100 mm (r < 100 mm).
Parts & tools for this job For 2011 Volkswagen Passat
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Passat 2011 cabin filter