Undercoated areas
- Make
- Volkswagen
- Model
- Passat NMS, US and China
- Year
- 2011–2019
- Section
- Underseal › Undercoated areas
Vehicle-specific paint informationUndercoated areas
Undercoated areas
Note
- Undercoating (stone-chipping protection) applied during repair work must be identical in appearance and thickness to the original undercoating.
- Water drainage holes must remain clear.
- All threaded studs and welded nuts with metric threads as well as all other studs and contact surfaces for assembly must be functional following the application of the undercoating.

Coat thickness: 0.3 mmcUndercoating
Coat thickness: 0.5 mm
Note
- Underseal (stone-chipping protection) applied during repair work must be identical in appearance and thickness to the original underseal.
- Water drainage holes must remain clear.
- All threaded studs and welded nuts with metric threads as well as all other studs and contact surfaces for assembly must be functional following the application of the underseal.

Coat thickness: 0.3 mmbUndercoating
Coat thickness: 1.2 mmcUndercoating
Coat thickness: 0.5 mm1Outer part of side panel2Body floor3Inner part of side memberDimension (x)
10 mm with decreasing thickness down to 0.3 mmDimension (y)
30 mmDimension (z)
35 mm
Note
- Undercoating (stone-chipping protection) applied during repair work must be identical in appearance and thickness to the original undercoating.
- Water drainage holes must remain clear.
- All threaded studs and welded nuts with metric threads as well as all other studs and contact surfaces for assembly must be functional following the application of the undercoating.

Coat thickness: 0.3 mmbUndercoating
Coat thickness: 1.2 mmcUndercoating
Coat thickness: 0.5 mm
Note
- Underseal (stone-chipping protection) applied during repair work must be identical in appearance and thickness to the original underseal.
- Water drainage holes must remain clear.
- All threaded studs and welded nuts with metric threads as well as all other studs and contact surfaces for assembly must be functional following the application of the underseal.

Coat thickness: 0.3 mm
Note
- Underseal (stone-chipping protection) applied during repair work must be identical in appearance and thickness to the original underseal.
- Water drainage holes must remain clear.
- All threaded studs and welded nuts with metric threads as well as all other studs and contact surfaces for assembly must be functional following the application of the underseal.

Coat thickness: 0.3 mm
Parts & tools for this job For 2011 Volkswagen Passat
- TOOLTrim removal tool kitSearch: trim removal tool kit
- PARTTouch-up paintSearch: Volkswagen touch up paint
- PARTPanel clip assortmentSearch: Volkswagen panel clips assortment
As an Amazon Associate we earn from qualifying purchases.