volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Application and ID|Page 1860 > < Application and ID|Page 1858
Page 9
background image

-

Install bearing caps 3 and 11 and tighten to 5 Nm + 45° (1/8) additional turn.

B - Exhaust Camshaft

-

Tighten bearing caps 6 and 10 alternately and in a diagonal sequence to 5 Nm + 45° (1/8) additional turn.

-

Install bearing caps 2 and 14 and tighten to 5 Nm + 45° (1/8) additional turn.

-

Install bearing caps 8 and 13 and tighten to 5 Nm + 45° (1/8) additional turn.

-

Install bearing caps 4 and 12 and tighten to 5 Nm + 45° (1/8) additional turn.

Continuation for Both Camshafts

-

Install the (T10068 A) into both camshaft grooves.

-

Before installing, check the control housing strainer for contamination, refer to => [ Checking Control Housing

Strainer for Contaminants ] See: Variable Valve Timing Cover / Housing/Service and Repair.

-

Before installing the control housing, lubricate the seals for the camshafts.

-

Lubricate the contact surface on the seals inside the control housing. Slowly slide the control housing over the camshaft seals.

-

Install the control housing and apply locking adhesive (D 000 600 A2) to the bolts - arrows -. Tighten the bolts to 8 Nm.

Application and ID|Page 1860 > < Application and ID|Page 1858