Checking combination valve
- Make
- Volkswagen
- Model
- Phaeton 3D
- Year
- 2002–2016
- Section
- Secondary air system › Checking combination valve
Checking combination valve
Special tools and workshop equipment requiredHand vacuum pump V.A.G 1390
Vacuum pipes and hose connections free of leaks.
Vacuum pipes not blocked or kinked.
Detach vacuum hose from secondary air inlet valve N112 from combination valve (arrow).

Note
- Do not use compressed air during the following check!
Connect hand vacuum pump V.A.G 1390 to vacuum connection on combination valve (arrow).

Detach pressure hose to combination valve at connection (arrow) and blow in softly. Combination valve must be closed.

Operate hand vacuum pump V.A.G 1390. Combination valve must open.
If combination valve does not open:
Renew combination valve Item.
Parts & tools for this job For 2002 Volkswagen Phaeton
- PARTEngine gasket setSearch: Volkswagen Phaeton 2002 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.