Preparatory measures for calibration
- Make
- Volkswagen
- Model
- Phaeton 3D
- Year
- 2002–2016
- Section
- Lane change assist › Preparatory measures for calibration
Preparatory measures for calibration
Extensive preliminary work is required before actual calibration can be carried out using vehicle diagnostic tester.
For the lane change assist, control units of different generations are installed. The control unit generation installed in the vehicle to be calibrated must be determined first so that the right values can be set afterwards, when installing the calibration platform VAS 6350.
Connect vehicle diagnostic testerChapter.
Select “Self-Diagnosis” mode in vehicle diagnostic tester.
Select the vehicle system “3C – lane change assist”:
On the top right of the display of the vehicle diagnostic tester the installed generation of the master control unit appears in the form of a part number with an “A”, “B” or “C” index. Allocate the part number of the control unit generation according to the following list:
| Control unit generation 1 | - Part number of master control unit up to 7L6.907.566 index A or B |
| Control unit generation 1.5 | - Part number of master control unit after 7L6.907.566 index C |

Connect vehicle diagnostic tester.
Note
- If a fault message appears in the display operating instructions of vehicle diagnostic tester.
Switch on ignition.
Attach three wheel bolt adapters AF 19 at each wheel centre mounting VAS 6350/1 for the wheel securing bolts.

Insert the measuring paddle on both wheel centre mountings VAS 6350/1 and secure these using the clamp nut.
Place the wheel centre mountings VAS 6350/1 on the wheel securing bolts of both rear wheels.
The turning centre of the wheel centre mounting must be in the turning centre of the wheel.Note
- Place wheel centre mountings VAS 6350/1 on wheels so that “anti-theft wheel bolts” are not connected to the wheel centre mountings.
Use clamp nuts to adjust measuring paddles so that they move freely just above the floor.
The measuring paddles must not be restricted in movement.The measuring paddles must be vertical.Position the calibration unit VAS 6350 at a distance of (a) to the rear wheels.

Switch on the spacing laser VAS 6350/2 with the ON button.

Indicated on display of VAS 6350/2:
“- - - m”Note
- The laser is switched on at the same time.
Hold the spacing laser VAS 6350/2(2) for the distance measurement flush with the stop bracket as shown in the illustration.

Ensure that the “laser beam” for distance measurement is at the bottom enlarged part on the measuring paddle (1).
If this is not the case, the height of the measuring paddles has to be correct with the aid of the clamp nuts on the wheel centre mounting VAS 6350/1.
Briefly press ON button to measure distance.

Indicated on display of VAS 6350/2:
“1,700 m” (specification: 1700 ± 2 mm).Repeat the measuring process from the left stop bracket to the measuring paddle on the rear left wheel.
Measured distance value must be identical on both sides.If both measured values are not identical, adjust calibration unit VAS 6350 accordingly.
Attach the calibration unit for lane change assist VAS 6350/4 on the rear left on the mounting of the calibration unit VAS 6350.

Note
- If assembled correctly, the mains power lead should be fitted to the bottom left of the calibration unit (as seen facing direction of normal travel).
According to determined control unit generation of vehicle, adjust calibration platform to following dimensions:
| Control unit generation | Height dimension (a)Remark | Left dimension (1)Remark |
|---|---|---|
| 1 (part number index A or B) | 650 mm | 674 mm |
| 1.5 (part number index C) | 650 mm | 850 mm |
Note
Note (arrow)
at the base of the calibration unit on the scale of the steel rule
(1).
Connect the calibration unit for lane change assist VAS 6350/4 to the mains.
Bring the calibration unit VAS 6350 to the horizontal position with the aid of the vial (sight glass) (arrow) by turning the plastic feet.

Put on “laser goggles”.

Switch on linear laser VAS 6350/3 on calibration unit VAS 6350.
Align the whole calibration unit VAS 6350 so that the laser beam is focused on the rear of the vehicle in the centre above the VW logo.
Check the spacing on the left and right again between the stop brackets of the calibration unit VAS 6350 and the measuring paddles (1) on the wheel mountings.

Calibrating lane change assist control unit → Chapter.
Parts & tools for this job For 2002 Volkswagen Phaeton
- TOOLDigital multimeterSearch: automotive digital multimeter
- PARTAssorted fuse kitSearch: car fuse assortment kit
- TOOLWire crimper and connector kitSearch: wire crimper connector kit
As an Amazon Associate we earn from qualifying purchases.