Removing quick release coupling
- Make
- Volkswagen
- Model
- Phaeton 3D
- Year
- 2002–2016
- Section
- Refrigerant circuit › Removing quick release coupling
Removing quick release coupling

Slide dust seal cap (1) away from coupling onto refrigerant line (2) until assembly area around coupling is free.

Extract refrigerant using air conditioner service station before opening refrigerant circuit. Comply with notes → Chapter.
Install release tool VAS 6127/3(2) in area of coupling. Cut outs on release tool must be in line with indicators.
Slide release tool (2) in (direction of arrow A) along air conditioner compressor line (1) until it is stopped by coupling housing (3).

Hold release tool in this position and pull coupling housing (1) in direction of arrow.