01 Fuel supply system - Petrol engines02 3-cylinder common rail engine (1.2 l, EA189)03 4-cyl. injection engine with timing chain04 3-cylinder injection engine (1.2 l engine, 4V, EA 111)05 4-cylinder common rail engine (1.5 l, 4V, turbocharger)06 4-cylinder diesel engine (1.6 l engine, common rail)07 4-cylinder direct injection engine (1.2 l engine, 2V, EA 111 turbocharger)08 5-speed manual gearbox 02T09 6-speed automatic gearbox 09G10 6-speed manual gearbox 02U11 5-speed manual gearbox 02R12 7-speed dual clutch gearbox 0AM13 Running gear, axles, steering14 Brake system15 Wheels and Tyres Guide16 Heating, air conditioning17 Electrical system18 Electrical: Communication19 General body repairs, exterior20 General body repairs, interior
Volkswagen Polo Mk5, India and Malaysia (2010-2020)16 · Heating, air conditioning
16 · Heating & A/C

Renewing dryer cartridge, Modine

Make
Volkswagen
Model
Polo Mk5, India and Malaysia
Year
2010–2020
Section
Refrigerant circuit › Renewing dryer cartridge, Modine
Heating, air conditioningRenewing dryer cartridge, Modine

Renewing dryer cartridge, Modine

Air conditioning system with refrigerant R134a

Note

  • Comply with notes → Chapter.
  • The dryer cartridge is located on left (in direction of travel) of condenser.
  • Under certain conditions, it is not necessary to renew the dryer bag every time that the refrigerant circuit is opened. Refer to ELSA under Air conditioning system with refrigerant R134aRep. gr.00Renewing components.
  • Depending on the vehicle equipment, it may be necessary to remove the condenser from the lock carrier to remove and install the dryer cartridge.

Special tools and workshop equipment requiredAir conditioner service stationInsert T70 T10128
W00-1241

Removing

Move lock carrier to service position General body repairs, exteriorRep. gr.50Lock carrier; Moving to and back from service position.

Unclip fan mounting.

Evacuate refrigerant circuit using air conditioner service station before opening refrigerant circuit.

Note

  • Releasing refrigerant into the environment is a punishable offence.
  • All components of the refrigerant circuit which have been opened must be sealed with suitable plugs to prevent moisture intrusion.

CAUTIONEscaping pressurised refrigerant can cause freezing.There is a risk of injury to the skin and parts of the body due to freezing.Wear protective gloves.Always wear safety goggles.Extract refrigerant, and open the refrigerant circuit immediately afterwards.If refrigerant circuit is not opened within 10 minutes after extracting refrigerant, extract refrigerant again before opening refrigerant circuit. Due to continued evaporation, pressure will build up in the refrigerant circuit.

Unscrew protective cap (1) using Torx insert T70 T10128.

N87-10588

Press sealing cap (1) into receiver.

N87-10590

Remove circlip (arrow) and pull sealing cap (1) out of condenser (2) using bolt M12.

Pull dryer cartridge out of condenser in direction of (arrow) using a commercially available pick-up tool.

N87-10589

Manufacture tool from welding wire (2 mm ∅) according to following dimensions.

N87-10591
a380 mmbmax. 7 mmcmax. 6 mm

To prevent damages to the condenser, it is essential to hook the welding wire on the strainer as shown in the illustration.

N87-10592

Carefully pull strainer (2) with welding wire (1) out of condenser.

Installing

Installation is carried out in the reverse order. When installing, note the following:

Insert new strainer into condenser.

Guide dryer cartridge into condenser.

N87-10590

Check sealing surfaces of receiver on condenser (2) for soiling or damage via opening.

Renew sealing cap (1) with relevant seal.

Lightly moisten sealing cap seal (1) with refrigerant oil before installation.

Ensure that seal sits correctly in sealing cap (1).

Insert circlip (arrow).

N87-10588

Screw in protective cap (1).

Charge refrigerant circuit Air conditioner with refrigerant R134a.