Self-diagnosis for convenience system
Fault table
Notes:
-
◆ The fault table is listed according to the 5 digit fault code on the left.
-
◆ Explanation of the fault types (e.g. "open circuit/short circuit to earth"):
=> Fault reader operating instructions
-
◆ Before renewing components indicated as being faulty, check the wiring and connectors to these components as well as the earth connections using current flow diagram. This is particularly relevant if faults are output as "occurring sporadically" (SP).
-
◆ The faults displayed can be localised using the test table.
|
---|
V.A.G 1551 print-out
|
Possible fault cause
|
Fault elimination
|
00000
|
|
|
No fault recognised
|
If "No fault recognised" appears after carrying out repairs self-diagnosis is ended
|
00849
|
|
|
S contact on ignition/starter switch -D
|
|
|
|
Undefined switch condition
|
- Terminal 15 OK. but S contact defective
|
- Read measured value block; Display group number 010
, Display zone 1
|
|
- Defective wiring or connectors
|
|
00946
|
|
|
Interior light -W
|
|
|
|
Short to positive
|
- Defective wiring or connectors
|
- Check wiring and connectors using current flow diagram
|
|
|
- Interior light or one of the reading lights are defective
|
- Renew interior light or defective reading light
|
|
---|
V.A.G 1551 print-out
|
Possible fault cause
|
Fault elimination
|
00955
|
|
|
Key 1
|
|
|
|
Adaption limit exceeded
|
- Key not adapted
- Key operated more than 200 times
- beyond range of system
|
- Read measured value block; display group number 013 => Page 01-134
, display zone 1...4
|
00956
|
|
|
Key 2
|
|
|
|
Adaption limit exceeded
|
|
|
00957
|
|
|
Key 3
|
|
|
|
Adaption limit exceeded
|
|
|
00958
|
|
|
Key 4
|
|
|
|
Adaption limit exceeded
|
|
|
|
---|
V.A.G 1551 print-out
|
Possible fault cause
|
Fault elimination
|
01044
|
|
|
Control unit incorrectly coded
|
|
|
|
|
- Control unit installed does not correspond to the vehicle equipment
- Control unit supplied is not programmed or not fully programmed
|
- Renew control unit
Inform part supplier of the problem
|
01131
|
|
|
Turn signal activation
|
|
|
|
Undefined switch position
|
- Defective wiring or connectors
|
- Check wiring and connectors using current flow diagram
Perform final control diagnosis
=> Page 01-123
|
|
|
- Fuse S144 defective
|
- Check fuses using current flow diagram or renew
|
|
---|
V.A.G 1551 print-out
|
Possible fault cause
|
Fault elimination
|
01134
|
|
|
Alarm horn -H12
|
|
|
|
Undefined switch position
|
- Defective wiring or connectors
|
- Check wiring and connectors using current flow diagram
Perform final control diagnosis
=> Page 01-123
|
|
|
- Fuse S111 defective
|
- Check fuses using current flow diagram or renew
|
|
|
- Alarm horn -H12 defective
|
- Renew alarm horn -H12
|
01135
|
|
|
Interior monitoring sensors
|
|
|
|
Open circuit
|
- Defective wiring or connectors
|
- Check wiring and connectors using current flow diagram
Read measured value block; Display group number 009 = Page 01-128
, display zone 4
|
|
|
- Sensors for monitoring interior not installed
|
- Check installation
|
|
Defective
|
- Sensors for monitoring interior defective
|
- Renew sensors for monitoring interior
|
|
---|
V.A.G 1551 print-out
|
Possible fault cause
|
Fault elimination
|
01179
|
|
|
Incorrect key programming
|
|
|
|
|
- Matching of keys (function 10) not performed correctly
|
- See description for matching keys with remote control, page 01-134
, display zones 1...41)
|
1)
Number of keys matched ("learnt") will be displayed.
|
---|
V.A.G 1551 print-out
|
Possible fault cause
|
Fault elimination
|
01330
|
|
|
Central control unit for convenience system -J393
|
|
|
|
Defective
|
- Central control unit for convenience system defective
|
- Renew convenience system central control unit
|
|
Voltage supply too high
|
- Battery A defective or discharged
- Voltage regulator C1 defective
- Alternator C defective
|
- Check wiring and connectors using current flow diagram
Read measured value block; Display group number 014 => Page 01-136
, display zone 1
|
|
Voltage supply too low
|
- Battery A defective or discharged
|
|
|
---|
V.A.G 1551 print-out
|
Possible fault cause
|
Fault elimination
|
01484
|
|
|
Central locking key button, lock
|
|
|
|
Short to earth1)
|
- Defective wiring or connectors
|
- Check wiring and connectors using current flow diagram
|
01485
|
|
|
Central locking key button, unlock
|
|
|
|
Short to earth1)
|
- Defective wiring or connectors
|
- Check wiring and connectors using current flow diagram
|
1)
Fault recorded if operated for longer than 10 seconds
|