volkswagen Workshop Repair Guides

Volkswagen Polo Workshop Service and Repair Manuals

Checking exhaust gas recirculation > < Vacuum hose connection diagram
3-cyl. diesel engine, Mechanics
Exhaust gas recirculation system
Checking exhaust gas recirculation valve (mechanical)
 
W00-0515

Special tools, workshop equipment, testers, measuring instruments and auxiliary items required

  • ◆ V.A.G 1390 Hand vacuum pump

Test sequence

  • ‒ Remove engine cover.
  • ‒ Remove connecting hose between charge air pipe and intake connecting flange.
  • ‒ Pull vacuum hose off (mechanical) exhaust gas recirculation valve.
 
N13-0268
  • ‒ Connect hand vacuum pump V.A.G 1390 to valve.
  • ‒ → Operate pump and observe membrane rod.
  • The membrane rod must move in direction of arrow.
  • ‒ Pull hand vacuum pump hose off exhaust gas recirculation valve.
  • The membrane rod must move back against the direction of arrow to its original position.

Checking exhaust gas recirculation > < Vacuum hose connection diagram