Verification for vehicles with butterfly (throttle), collection tank and regulating valve for the air conditioning compressor -N280- (with air conditioning compressor with external adjustment device) |
Note t
| Connect the climate control recovery, recycling, refilling, and cleaning equipment → Chapter. |
–
| Start the engine and keep it running at a speed of 2,000 rpm. |
–
| Observe the pressure gauges on the Climate control recovery, recycling and refill set or EQ 7098 -VAS 6008-. |
Note t
| The operating pressures of the Adjustment valve for the air conditioning compressor -N280- and of the Radiator fan -V7- vary from vehicle to vehicle. |
t
| The valve terminal of the low pressure switch or next to the evaporator should only be used in vehicles not equipped with a low pressure service terminal and in which the terminals of the air conditioning compressor or of the collection tank are not accessible (measuring accuracy). Only applicable to certain vehicles. |
|
|
|