Note The blower motors for heater unit and air conditioning unit differ. Note part numbers! |
Installation is carried out in the reverse order. When installing, note the following: |
Caution The fan wheel can break or bend (imbalance). |
if pressure is applied when fitting fresh air blower -V2- on fan wheel. |
Apply pressure only to the shaft when pressing fresh air blower -V2- into its housing. |
|
t
| The connector must engage correctly in the housing. |
t
| The rubber elements of the motor bracket must project fully out of housing. |
|
|
|