01 Fuel supply system – petrol engines02 4-cylinder injection engine (1.6 l engine)03 4-cyl. injection engine with timing chain04 5-speed manual gearbox 02T05 6-speed automatic gearbox 09G06 6-speed manual gearbox 02U07 Running gear, axles, steering08 Brake system09 Wheels and Tyres Guide10 Heating, air conditioning11 Electrical system12 Electrical: Communication13 General body repairs, interior14 General body repairs, exterior
Volkswagen Polo Sedan, Russia (2010-2020)10 · Heating, air conditioning
10 · Heating & A/C

Removing and installing dryer cartridge

Make
Volkswagen
Model
Polo Sedan, Russia
Year
2010–2020
Section
Refrigerant circuit › Removing and installing dryer cartridge
Heating, air conditioningRemoving and installing dryer cartridge

Removing and installing dryer cartridge

Air conditioning system with refrigerant R134a

Note

  • Comply with notes → Chapter.
  • The dryer cartridge is located on left (in direction of travel) of condenser.
  • Under certain conditions, it is not necessary to renew the desiccant bag every time that the refrigerant circuit is opened. Refer to ELSA under Air conditioning system with refrigerant R134aRep. gr.00Renewing components.
  • Depending on the vehicle equipment, it may be necessary to remove the condenser from the lock carrier to remove and install the dryer cartridge.

Special tools and workshop equipment requiredAir conditioner service stationInsert T70 T10128
W00-1241

Removing

Move lock carrier to service position General body repairs, exteriorRep. gr.50Lock carrier; Moving to and back from service position.

Unclip fan mounting.

Evacuate refrigerant circuit using air conditioner service station before opening refrigerant circuit.

Note

  • Releasing refrigerant into the environment is a punishable offence.
  • All components of the refrigerant circuit which have been opened must be sealed with suitable plugs to prevent moisture intrusion.

CAUTIONEscaping pressurised refrigerant can cause freezing.There is a risk of injury to the skin and parts of the body due to freezing.Always wear safety gloves.Always wear safety goggles.Extract refrigerant, and open the refrigerant circuit immediately afterwards.If refrigerant circuit is not opened within 10 minutes after extracting refrigerant, extract refrigerant again before opening refrigerant circuit. Due to continued evaporation, pressure will build up in the refrigerant circuit.

Unscrew protective cap (1) using Torx insert T70 T10128.

N87-10588

Press sealing cap (1) slightly into receiver.

N87-10590

Remove circlip (arrow) and pull out cover (1) from condenser (2) using M12 bolt.

N87-10617

Pull dryer cartridge (1) out of receiver (2).

Installing

Install in reverse order. Note the following when doing this:

N87-10590

Check sealing surfaces of receiver on condenser (2) for soiling or damage via opening.

Renew sealing cap (1) with relevant seal.

Lightly moisten sealing cap seal (1) with refrigerant oil before installation.

Ensure that seal sits correctly in sealing cap (1).

Insert circlip (arrow).

N87-10588

Screw in protective cap (1).

Reinstall remaining removed components.

Charge refrigerant circuit Air conditioner with refrigerant R134a.

Parts & tools for this job For 2010 Volkswagen Polo