Current draw test
- Make
- Volkswagen
- Model
- Polo Vivo, South Africa
- Year
- 2010–2017
- Section
- Checking battery › Current draw test
Current draw test
Warning Batteries where the magic eye is colourless or light yellow must not be checked or charged. Do not slave/jump start the vehicle!
Danger of explosion when checking and charging or slave/jump starting.
These batteries must be renewed.
To quickly ascertain the condition of a discharged battery, the current draw test whilst charging will help to ascertain the condition of a discharged battery to establish whether a battery must be replaced or fully recharged.
1Starting capability sufficient2Starting capability poor3Starting capability very poor4Cannot be tested - charge battery and repeat testand when the tester will not switch on (no LED, no printout)Depending on the test result with battery tester with printer VAS 5097AChapter, further procedures or tests may be required before making a final decision on the condition of the battery.
Performing a current draw test whilst charging a battery will quickly establish whether a partly or fully discharged battery → Chapter can be recharged to return it to a serviceable condition.
- Battery temperature must be at least ≥ +10°C when charging a battery.
- The charger must be capable of providing a 30 A charge current, as for example with VAS 5095A, VAS 5900, VAS 5903.
- The current draw on the battery must be measured with a 100A pick-up clamp, for example VAS 5051B/7, when charging with battery charger VAS 5095A. Battery charger VAS 5900 and battery charger VAS 5903 display the current draw on the unit.
Connect battery to battery charger and start charging sequence.
Measure charge current of battery after 5 minutes.
The charge current must be more than 10% of the nominal capacity 5 minutes after starting the charging sequence.
For a 60 Ah battery the charge current must the higher than 6A after 5 minutes of starting the charging sequence.
Note
- For Eos with two 6V absorbent glass mat batteries, the charge current must only be 5% higher than the nominal capacity of the battery. Example for Eos: the 50 Ah battery must have a charge current higher than 2.5A after 5 minutes of starting the charging sequence.
Charge battery full when the charge current is higher than 10% of the nominal capacity (observe exception for Eos in above note)
Perform battery load test after allowing battery to rest for two hours → Chapter.
If the charge current, in Ampere, lies below 10% of the nominal capacity after 5 minutes of starting the charging sequence (5% for the 2 x 6 Volt batteries in Eos) (example for 60 Ah battery < 6A), renew battery. For Guarantee and ex-gratia cases: complete battery test sheet and keep it with the battery.
Parts & tools for this job For 2010 Volkswagen Polo
- TOOLBattery testerSearch: car battery tester
- TOOLDigital multimeterSearch: automotive digital multimeter
- TOOLBattery terminal cleanerSearch: battery terminal cleaner