01 4-cyl. injection engine with timing chain02 4-cyl engine03 Fault finding; Power transmission04 5-speed manual gearbox 02T05 6-speed automatic gearbox 09G06 09G Gearbox07 02R Gearbox08 02T Gearbox09 Brake systems10 Wheels and Tyres Guide: Standard11 Running gear; axles; steering12 Running gear, axles, steering13 Brakes14 Wheels and Tyres Guide15 Heating; air-conditioning16 Electrical: General Information17 Electrical: Communication18 Electrical19 General body repairs, exterior20 General body repairs, interior21 Body Interior
Volkswagen Polo Vivo, South Africa (2010-2017)16 · Electrical: General Information
16 · Electrical

Current draw test

Make
Volkswagen
Model
Polo Vivo, South Africa
Year
2010–2017
Section
Checking battery › Current draw test
Electrical: General InformationCurrent draw test

Current draw test

Warning Batteries where the magic eye is colourless or light yellow must not be checked or charged. Do not slave/jump start the vehicle!
Danger of explosion when checking and charging or slave/jump starting.
These batteries must be renewed.

To quickly ascertain the condition of a discharged battery, the current draw test whilst charging will help to ascertain the condition of a discharged battery to establish whether a battery must be replaced or fully recharged.

The current draw test must be carried out when the test result with battery tester with printer VAS 5097A is as follows:

1Starting capability sufficient2Starting capability poor3Starting capability very poor4Cannot be tested - charge battery and repeat testand when the tester will not switch on (no LED, no printout)

Depending on the test result with battery tester with printer VAS 5097AChapter, further procedures or tests may be required before making a final decision on the condition of the battery.

Performing a current draw test whilst charging a battery will quickly establish whether a partly or fully discharged battery → Chapter can be recharged to return it to a serviceable condition.

Test prerequisites

  • Battery temperature must be at least ≥ +10°C when charging a battery.
  • The charger must be capable of providing a 30 A charge current, as for example with VAS 5095A, VAS 5900, VAS 5903.
  • The current draw on the battery must be measured with a 100A pick-up clamp, for example VAS 5051B/7, when charging with battery charger VAS 5095A. Battery charger VAS 5900 and battery charger VAS 5903 display the current draw on the unit.

Connect battery to battery charger and start charging sequence.

Measure charge current of battery after 5 minutes.

Test result

The charge current must be more than 10% of the nominal capacity 5 minutes after starting the charging sequence.

For example

For a 60 Ah battery the charge current must the higher than 6A after 5 minutes of starting the charging sequence.

Note

  • For Eos with two 6V absorbent glass mat batteries, the charge current must only be 5% higher than the nominal capacity of the battery. Example for Eos: the 50 Ah battery must have a charge current higher than 2.5A after 5 minutes of starting the charging sequence.

Charge battery full when the charge current is higher than 10% of the nominal capacity (observe exception for Eos in above note)

Perform battery load test after allowing battery to rest for two hours → Chapter.

If the charge current, in Ampere, lies below 10% of the nominal capacity after 5 minutes of starting the charging sequence (5% for the 2 x 6 Volt batteries in Eos) (example for 60 Ah battery < 6A), renew battery. For Guarantee and ex-gratia cases: complete battery test sheet and keep it with the battery.